Tech Settings

Swing Setting Tip

Temperature swing, sometimes called differential or cycle rate, can be customized 

for this individual application.  For most applications choose a swing setting that is 

as long as possible without making the occupants uncomfortable.

Technician Setup Menu

Tech Settings

Adjustment Options Default

Tech Settings

LCD Will Show

12

Note:

In many systems with no emergency heat relay a jumper can be installed 

between W/E and W2.

This feature allows the installer 

to change the calibration of the 

room temperature display. For 

example, if the thermostat reads 

70˚ and you would like it to read 

72˚ then 2.

Tech Setup Steps

Room

Temperature

Calibration

0˚F

You can adjust the room 

temperature display to read 

up to 4˚above or below the 

factory calibrated reading.

Adjustment Options

Default

LCD Will Show

0

This thermostat has a technician setup menu for easy installer 

configuration. To set up the thermostat for your particular application:

1. Hold down the + and - buttons together for 3 seconds. 

2. Use the + and - buttons to modify a setting. Use the Fan button to 

go back a step and use the system button to go forward a step.

3. To exit Tech Settings, press and hold the + and - button together for 

3 seconds or wait 60 seconds. 

The swing setting often called 

“cycle rate”, “differential” or

“anticipation” is adjustable. A 

smaller swing setting will cause 

more frequent cycles and a larger 

swing setting will cause fewer 

cycles.

Cooling 

Swing

The cooling swing setting 

is adjustable from 0.2˚ to 

2˚. For example: A swing 

setting of 0.5˚ will turn the 

cooling on at approximately 

0.5˚ above the setpoint 

and turn the cooling off at 

approximately 0.5˚ below 

the setpoint.

0.5

0.5˚

Swing Setting Tip

The second stage will turn on at 2x the swing setting.  The second stage will 

turn off when 1x the swing is reached. For example, if the swing setting is .5 

degrees for heating and the thermostat is set at 70

˚

F, the first stage will turn 

on at approximately 69.5

˚

F.  The second stage will turn on at 69

˚

F. The second 

stage will turn off at 69.5

˚

F and the first will turn off at 70.5

˚

F.  If the third 

stage is used, it will turn on at 68.5

˚

F and turn off at approximately 69

˚

F.

COOL SWING

CALIBRATE

PTAC Medium 

Fan Speed 

Terminal 

This setting will select the 

terminal for medium fan speed 

operations.  The selected terminal 

cannot be used for reversing valve 

operations when heat pump is 

enabled. 

Use the         and         buttons 

to select O/B terminals.

0

0

The swing setting often called 

“cycle rate”, “differential”, or 

“anticipation” is adjustable. A 

smaller swing setting will cause 

more frequent cycles and a larger 

swing setting will cause fewer 

cycles.

Heating 

Swing

The heating swing setting 

is adjustable from 0.2˚ to 

2˚. For example: A swing 

setting of 0.5˚ will turn the 

heating on at approximate-

ly 0.5˚ below the setpoint 

and turn the heating off at 

0.5˚ above the setpoint.

0.4˚

0.4

HEAT SWING

MED FAN TERM

PTAC Mode

This setting allows the thermostat 

to operate a PTAC. This will allow 

for multiple fan speeds selectable 

in the next two tech settings.

Use the         and         buttons 

to select ON/OFF.

OFF

OF

PTAC MODE

This setting allows you to choose 

the number of fan speeds the 

thermostat will control.  

G = Low Speed Fan

B/O = Medieum Speed Fan

Y2 = High Speed Fan

PTAC Fan

Speeds

(Only displayed if 

PTAC mode is ON) 

2

2

FAN SPEEDS

When turned on the thermostat 

will operate a heat pump.  EM. 

Heat will show as an option in the 

system switch tech setting.  

Use the         and         button to 

adjust.  

Heat Pump

OFF configures the 

thermostat for conventional 

systems. 

ON configures the 

thermostat for heat pump 

systems.

OFF

OF

HEAT PUMP

Use the         and         buttons 

to select , 2 or 3.

1. Speeds: ON, Auto

2. Speeds: Low, High, Auto

3. Speeds: Low, Med, High, 

Auto

Wiring Diagrams

Tech Settings

Tech Settings

Adjustment Options

Default

LCD Will Show

This setting allows you to select 

the number of heat and cool

stages.

Select GAS to have the system 

control the fan during a call for 

heat, select Electric to have the 

thermostat control the fan during 

a call for heat.

Note: If heat pump is set to “ON” this 

step will not show, and will default 

to ELECTRIC. 

Electric or Gas

Fan Operation

(Only displayed if 

heat pump is set 

to OFF)

Use          and        buttons to 

change the setting.

FAN SET

System 

Stages

2H

GAS

GAS

System Set

Use the          or           buttons 

until the desired application 

is flashing. AUTO = (Auto 

Changeover) 

Heat

Off

Cool

SYSTEM SET

Off

Em.Heat

AutoCool

You can configure the system 

switch for the particular 

application.  Heat - Off - Cool, 

Heat - Off, Cool - Off, Heat - Off - 

Cool – Auto.  

Note: Emergency Heat is available 

in heat pump mode only. 

Dual Fuel 

Auxiliary For 

Heat Pump

(Only displayed if 

heat pump is set 

to ON)

OFF

This setting allows the system 

to run Gas, Oil, Propane or any 

other types of auxiliary heat.  The 

thermostat will default to electric 

auxiliary heat in heat pump 

applications. 

OF

DUAL FUEL

Use the         and         but-

tons to select ON/OFF. 

SET 
STAGES

2H2C

Use the         and         buttons 

to select 1H/1C, 1H/2C, 

2H/1C, 2H/2C, 3H/1C, 3H/2C, 

4H/2C.

Note: Heat and cool choices 

are limited based on 

conventional, heat pump, or 

PTAC system configuration.

This feature allows the thermostat 

to keep multiple stages of heat or 

cool energized until the setpoint 

is satisfied. 

Satisfy 

Setpoint

Staging 

(Only displayed 

if there are more 

than one stage of 

heat or cool)

Use the         or          buttons 

to turn on of off.

SS STAGING

OF

OFF

Typical 3H/2C or 2H/1C Heat Pump System

RC
RH

Y
C

W/E

G

W2

Y2

COMPRESSOR

RELAY

FAN RELAY

AUXILIARY

HEAT RELAY 

COMPRESSOR

RELAY 2

EMERGENCY 

HEAT RELAY

COOL CHANGE

OVER VALVE

HEAT CHANGE

OVER VALVE

C

R

L2

L1

(HOT)

O
B

(Only displayed 

if PTAC mode is 

ON and PTAC fan 

 speeds is set to 3)