Tech Settings 

Tech Settings

Adjustment Options

Default

LCD Will Show

This feature allows a delay to 

occur if an additional stage is 

needed. This allows the previous 

stage extra time to satisfy the 

setpoint. 

Note: Will not show if using 

outdoor sensor with balance point 

temperature. 

Staging 

Delay

 

(Only displayed 

if there are more 

than one stage of 

heat or cool)

Use the         or          key to 

select OFF, 5, 10, 15, 30, 45, 

60, or 90 minutes. 

STAGING 
DELAY

OF

This feature allows the installer 

to select the minimum run 

time for the compressor. For 

example, a setting of 4 will force 

the compressor to run for at 

least 4 minutes every time the 

compressor turns on, regardless 

of the room temperature. 

Minimum 

Compressor 

On Time

You can set the minimum 

compressor run time to 

“OFF”, “3”, “4”, or “5” minutes. 

If 3, 4 or 5 is selected, the 

compressor will run for at 

least the selected time 

before turning off.  Use the       

        and          buttons to 

change the setting. 

MIN COMP ON

OF

OFF

OFF

The compressor short cycle delay 

protects the compressor from 

“short cycling”.  This feature will 

not altlow the compressor to be 

turned on for 5 minutes after it 

was last turned off. 

Compressor 

Short Cycle 

Delay

ON

Selecting “ON” will not allow 

the compressor to be turned 

on for 5 minutes after the 

last time the compressor was 

on. Select “OFF” to remove 

this delay. Use the        and 

buttons to change the 

setting. 

Cooling Fan 

Delay

The cooling fan delay setting will 

delay the fan from coming on in 

cool mode and keep it running 

after the compressor shuts off 

for a short time to save energy in 

some systems. 

You can set the cooling fan 

delay to OFF, 10, 30, 60 or 90 

seconds. If 10, 30, 60, or 90 

is selected the fan will not 

turn on for that many seconds 

when there is a call for cool 

and will run for that many 

seconds after satisfying a call 

for cool. 

OFF

COMP DELAY

COOL FAN DL

OF

This feature allows you to set 

a maximum heating setpoint 

limit. The setpoint temperature 

cannot be raised above this 

value.

Heat 

Setpoint 

Limit

This feature allows you to set a 

minimum cooling setpoint limit. 

The setpoint temperature cannot 

be lowered below this value.  

Cool 

Setpoint

Limit

Use the         or         key to 

select the minimum cooling 

setpoint. 

Use the         or          key to 

select the maximum heat 

setpoint and the minimum 

cooling setpoint. 

HEAT LIMIT

HE

90˚F

COOL LIMIT

CO

44˚F

Tech Settings

Tech Settings 

Tech Settings

Adjustment Options

Default

LCD Will Show

This feature allows you to 

display temperatures in either 

Fahrenheit or Celsius. 

˚F or ˚C

˚

F for Fahrenheit

˚

C for Celsius 

˚F

F OR C SET

F

o

The display light can be 

configured to stay on all the 

time or turn on when any key 

is pressed.  There are LOW and 

HIGH selections for continuous 

ON selection.  

NOTE:  The thermostat will need to 

be hardwired in order for the LOW 

and HIGH display light functions 

to work properly.  “ALWAYS ON LIT” 

will alternate in the text field with 

“HARDWIRE ONLY” when HIGH is se-

lected.  These prompts will alternate 

every three seconds.

If the thermostat is hardwired 

this feature will default to LOW.

Display 

Light

Use the         and         

buttons to select OFF, LOW, 

or HIGH. 

OFF configures the display 

light to come on when the 

light key or any button is 

pressed. 

LOW configures the display 

light to stay on at a low 

intensity constantly.  When a 

button is pressed, the display 

light will transition to high 

intensity. 

HIGH configures the display 

light to remain on at high 

intensity all the time.

ALWAYS ON LIT

dL

OFF

HARDWIRE ONLY

dL

LOW

If 

Hardwired

If Battery

Powered

15

16

Specifications

Specifications

The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)

The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)

Load Rating............................................... 1 amp per terminal, 1.5 amp 

                                                                      maximum all terminals combined

Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚

                                                                             Cooling is adjustable from 0.2˚ to 2.0˚

Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz 

                                                                      for hardwire

                                                                      Battery power from 2 AA Alkaline 

                                                                      batteries

Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)

Operating humidity .............................. 90% non-condensing maximum

Dimensions of thermostat ................. 4.7” W x 4.3” H x 0.9” D