Tech Settings

Tech Settings 

You can configure this thermostat 

to have 7 Days,  5+1+1 program-

ming or non programmable.

Program

Options

5d

Use the         and          key to se-

lect 

7d

 for 7 Day, 

5d

 for 5+1+1, 

or 

0d

 for non programmable.

Tech Settings

Adjustment Options

Default

LCD Will Show

You can configure the thermostat to 

operate a 3 stage heat pump system.

2H 2C = 2 heat, 2 cool

3H 2C = 3 heat, 2 cool

This feature only shows if Technician 

Setup Step for HEAT PUMP is set 

to ON.

Use the          or          key to 

change between 2H and 3H.

2H will use Y1 as first stage 

and W2 as auxiliary.

3H will use Y1 as first stage, 

Y2 as second stage and W2 as 

auxiliary.

Stages of

Heat

2H

The cooling fan delay setting will 

delay the fan from coming on in 

cool mode and keep running after 

the compressor shuts off for a 

short time to save energy in some 

systems.

You can select the cooling fan 

delay from “OFF”, “15”, “30”, “60” 

or “90” seconds.  If 15, 30, 60 or 

90 is selected the fan will not 

turn on for that many seconds 

when there is a call for cool and 

will run for that many seconds 

after satisfying a call for cool.

Cooling 

Fan Delay

OFF

Next Step

Prev Step

Next Step

Prev Step

You can select either a 12 or 24 hour 

clock setting.

12 or 24 

Hour Clock

12

Use the         and          to select 12 

or 24 hour clock.

Select GAS for systems that control 

the fan during a call for heat. Select 

ELEC to have the thermostat control 

the fan during a call for heat.

Fan 

Operation

GAS

GAS - GS

or

ELEC - EL

CLOK

Next

Prev 

Done

FAN

Next

Prev 

Done

GA

PROG

Next

Prev 

Done

5d

When turned on the thermostat will 

operate a heat pump.

1. EM. Heat will show as an option in 

the system switch.

2. Y will be first stage of heat & cool, 

W/E will be emergency heat relay & 

W2 will be axiliary heat relay.

Heat Pump

OFF

 configures the thermostat 

for non-heat pump systems.

ON

 configures the thermostat 

for heat pump systems.

HPUM

Next

Prev 

Done

OF

Tech Settings

Adjustment Options

Default

LCD Will Show

For Dual Fuel applications (Gas/

Fossil fuel Auxiliary Heat), turn this 

setting 

ON

 to 

LOCKOUT

 the Heat 

Pump (Y) when Auxiliary Heat (W2) 

is on. If desired - This can also be 

used with Electric Auxiliary.

OFF

OFF

 Will allow Y(1st stage of 

Heat) and W2 (Aux Heat) to run 

together if called for.

ON

 Will de-energize Y terminal 

45 seconds after a call for 

Auxiliary Heat (W2).

You can configure the system switch 

for the particular application:

Heat - Off - Cool, Heat - Off, Cool 

- Off.

Note: EM. Heat will show if in heat 

pump mode.

System

Switch 

Heat 

Off

Cool

SYST

Next

Prev 

Done

GAUX

Next

Prev 

Done

OF

Use the           or            key 

until the desired application is 

flashing.

Cool

Heat Off

HPUM

2H

FNdL

OF

OFF

This feature allows the installer 

to change the callibration of the 

ambient humidity displayed.

Humidity

Calibration

0

Use the         and          key to 

adjust the calib/-3.

Each one unit of adjustment 

amounts to approximately 5%.

This feature adds humidity when 

system key is in HEAT.

Note: See terminal Options 

on page 15.

Humidify

Use the         and          key to 

turn on or off. If ON is selected 

the humidity will be displayed 

on the main screen and HUM 

terminal will energize when 

humidity setpoint is above 

ambient humidity in Heat mode.

This feature removes humidity 

when system key is in COOL.

Note: See terminal Options 

on page 15.

Dehumidify

HUMd

Next

Prev 

Done

dHUM

Next

Prev 

Done

OF

HCAL

Next

Prev 

Done

 0

This feature forces the A/C to run 

longer to remove humidity when 

needed. The A/C will “over cool” the 

room a few  degrees until humidity 

reaches the desired setpoint.

Dehumidify

with AC

dHAC

Next

Prev 

Done

NO

OF

OFF

Use the         and          key to 

turn on or off. If ON is selected 

the humidity will be displayed 

on the main screen and DUM 

terminal will energize when 

humidity setpoint is below 

ambient humidity in Cool mode.

OFF

Use the         and          key to 

select YES or NO.

If selected YES allows over 

cooling to be used to control 

humidity in Cool mode. If NO is 

selected the system will not use 

over cooling.

Setting the Humidity

Setting the Humidity

Setting Target Humidity Setpoint

Follow the steps below to change your target humidity setpoint.
Press the

 HUMIDITY

 key

Use the         or         key to select the target humidity setpoint.

Press 

DONE

 when completed.

Note:

The target humidity setpoint is not programmable. Unlike 

temperature, humidity does not change quickly and should not 

be programmed.
Humidity is only energized during heat. Dehumidify is only 

energized during cool. Heat and Cool each have their own target 

setpoints.

Setting Target Humidity Setpoint

Ambient humidity will flash in the time field when Humidify or De-Humidify is 

set to 

ON.

HON

 will also flash when the Humidity terminal is energized. 

dON

 will also 

flash when the De-Humidify terminal is energized.

HUMIDITY KEY

TARGET HUMIDITY 

SETPOINT KEYS

DAY AND TIME

AMBIENT HUMIDITY

HON 

(Humidity Energized)

dON 

(De-Humidity Energized)

10:03

36

Humidity

       %

Recommended Heating Settings:

Increasing Humidity

The table on the right shows recommended indoor humidity levels in relation 

to outdoor temperatures during heating (adding humidity).

Consult your professional HVAC technician for recommended settings for 

your climate.

Recommended Cooling Settings:

Outside 

Temperature (0˚F

Recommended

Relative Humidity

+20˚ and above

35% to 40%

+10˚

30%

25%

-10˚

20%

-20˚

15%

Dual Fuel

Auxiliary 

for Heat 

Pump

Will only 

appear if 

Heat pump

setting is 

turned ON.

SYSTEM

FAN

Humidity

SYSTEM

FAN

Humidity