background image

Features

Temporary and Permanent Hold Feature

When cool or heat is turned on, the thermostat will display

 HOLD

 

and 

RUN SCHED

 on the left of your screen when you press the

         or           button. 

Temporary Hold

: At this time if you do nothing, the temperature will 

remain at this setpoint temporarily for 4 hours.

Permanent Hold

:  If you press the 

HOLD

 key on the left of your 

screen, you will see 

HOLD

 appear below the setpoint temperature in 

the display. The thermostat will now permanently stay at this 

setpoint and can be adjusted using the            or           keys.

To Return to Running Schedule

:  Press the 

RUN SCHED

 button on 

the left of your screen to exit either temporary or permanent hold.

Filter Change Reminder

If your installing contractor has configured the thermostat to remind 

you when the air filter needs to be changed, you will see 

FILT 

in the 

display when your air filter needs to be changed.

Resetting the filter change reminder:

 When 

FILT

 reminder is 

displayed, you should change your air filter and reset the reminder 

by holding down the second button from the top left side of the 

thermostat for 3 seconds.

(If using programming)

Gently slide a screwdriver into the 

bottom edge of the badge. Gently turn 

the screwdriver counter clockwise.  The 

badge is held on by a magnet in the well 

of the battery door.  The badge should pry 

off easily.  

DO NOT USE FORCE.

About The Private Label Badge

All of our thermostats use the same universal magnetic badge.  Visit the 

company website to learn more about our free private label program.

Magnet in door

Use the bevel on lower ridge

Set Time
1. 

 

With system switch set to OFF, press the 

MENU

 button

2.

  Press 

SET TIME

3.

  Day of the week will be flashing.  Use the              or              key 

      to select the current day of the week.

4.

  Press 

NEXT STEP

5.

  The current hour is flashing.  Use the              or              key to 

      select the current hour.  When using 12-hour time, make sure 

      the correct a.m. or p.m. choice is selected.

6.

  Press 

NEXT STEP

7.

  Minutes are now flashing.  Use the              or              key to 

      select current minutes.

8.

  Press 

DONE

 when completed.

(If using programming)

Programming

Specifications

The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)

The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)

Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚

                                                                         Cooling is adjustable from 0.2˚ to 2.0˚

Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz 

                                                                      for hardwire

                                                                      Battery power from 2 AA Alkaline 

                                                                      batteries

Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)

Operating humidity .............................. 90% non-condensing maximum

Dimensions of thermostat ................. 4.7”W x 4.4”H x 1.1”D

Specifications