Thermostat Quick Reference

Thermostat Quick Reference

Indicates the current room temperature
Time and day of the week

Setpoint:

 Displays the user selectable setpoint temperature.

Hold:

 Is displayed when the thermostat program is permanently overridden.

System Operation Indicators:

The 

COOL

HEAT

 or 

FAN

 icon will display when the 

COOL

HEAT 

or 

FAN 

is 

on. 

NOTE

: The compressor delay feature is active if these icons are flashing. 

The compressor will not turn on until the 5 minute delay has elapsed.

1
2
3

7

Low Battery Indicator: 

Replace batteries when this indicator is shown.

Program Menu Options: 

Show different options during programming.

Period Icons -

 This thermostat can have 2 or 4 programmable time periods 

per day. Icons are displayed for 4 time periods. Occupied and Unoccupied 

will display in the text field for 2c and 4c time periods.

8

2

8

3

1

7

Summary of Contents for TP-S-955C

Page 1: ...Operation Manual Operation Manual...

Page 2: ...7 8 14 1 Una version en espa ol de este manual se puede descargar en la pagina web de la compa ia Equipment damage hazard Do not operate the cooling system if the outdoor temperature is below 50 F 10...

Page 3: ...ling system is on A Note About Programmable Fan The programmable fan feature will run the fan continuously during any time period it is programmed to be on This is the best way to keep the air circula...

Page 4: ...n return to either 55 F or 85 F After day 63 the batteries must be replaced immediately to avoid freezing or overheating because the thermostat will shut the unit off until the batteries are changed I...

Page 5: ...en the COOL HEAT or FAN is on NOTE The compressor delay feature is active if these icons are flashing The compressor will not turn on until the 5 minute delay has elapsed 1 2 3 7 Low Battery Indicator...

Page 6: ...using 12 hour time make sure the correct a m or p m choice is selected 6 Press Next Step 7 Minutes are now flashing Use the or key to select current minutes 8 Press DONE when completed 1 Select HEAT o...

Page 7: ...nday WAKE OCC1 time period fLEAVE UNOCC1 time period RETURN OCC2 time period and for the Sunday SLEEP UNOCC2 time period Sunday Monday Repeat steps 4 through 6 for the remaining days of the week 1 Sel...

Page 8: ...key to make your time selection for that day s OCCUPIED time period Note If you want the fan to run continuously during this time period select ON with the FAN key Monday To customize your 7 day prog...

Page 9: ...UNOCCUPIED time period Temporary Hold The thermostat will display HOLD and Run Scheduleon the bottom of the screen when you press the or key If you do nothing the temperature will remain at this setpo...

Page 10: ...te the form below and mail it to the address shown Warranty Registration Complete form and mail to Thermostat Warranty Registration P O Box 3377 Springfield MO 65808 3377 Online Mail If your HVAC cont...

Page 11: ...Cut Out For Warranty Registration www vivecomfort com...