background image

Installation Manual

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes

No

Power Type

Battery Power*

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Wireless Type Selection

Installation Tips

Thermostat Quick Reference

Private Label Badge

Wireless Communication Tips

Reestablishing Communication

Wiring

Technician Setup Menu

Setting the Humidity

Programming

Specifications

 

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en español de este 

manual se puede descargar en 

la pagina web de la compañia.

Rev. 1821

     U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

3-8

13

2

Yes
Yes

14-18

Wireless Type Selection

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

Installation Tips

19-28

29

11

9-10

The thermostat and base module contain selectable wireless 

communication options. Each component has a jumper switch label 

FSK and ASK. Default setting: FSK.

• All components must be set to the same position for wireless 

  communication.

• Both modes utilize a 916 MHz frequency.

• FSK: frequency-shift keying, is the recommended mode.

• ASK: amplitude-shift keying, should be selected when using 

  components that can not communicate with FSK.

The images below illustrate the location of jumper switches for each 

item that has one. Note only the thermostat and Base Module are 

included in this package.

Back

FSK/ASK Switch

Back

FSK/ASK Switch

955WH

ROSW

The table below lists the mode options for T955WH 

wireless thermostat and its accessories.

*Compatible with Z955W - Wireless Zoning Controller

Component

Mode Options

955WH Thermostat
955WH Thermostat Base Module
RISW - Indoor Remote*
ROSW - Outdoor Remote*
RISW- Indoor Remote
ROSW - Outdoor Remote
W150W - Wireless Repeater

FSK or ASK
FSK or ASK
FSK or ASK
FSK or ASK

ASK
ASK
ASK

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Thermostat Subbase Installation

12

30-38

39

Humidity
Dual Fuel

Yes
Yes

* If you are using remote 

sensors the thermostat 

must be hardwired.

C

R

FSK / ASK

RESET

+

 

C

 

R

FSK/ASK

+

B1

 ASK/FS

K

RISW

 A

SK

/F

SK

RE

SET

IM

S

 A

SK

 F

SK

 A

SK

 FS

K

JP1

JP

3

ASK/FSK

BASE MODULE

 ASK/FSK

c
o

Vive Comfort

Toll Free : 888-776-1427 

Web: www.vivecomfort.com

Hours of Operation: M-F 9AM - 6PM Eastern 

TP-S-955WH

P.O. Box 3377

Springfield, MO 65804

Summary of Contents for TP-S-955WH

Page 1: ...ctable wireless communication options Each component has a jumper switch label FSK and ASK Default setting FSK All components must be set to the same position for wireless communication Both modes uti...

Page 2: ...cal Mount Horizontal Mount For horizontal mount put one screw on the left and one screw on the right For vertical mount put one screw on the top and one screw on the bottom To connect the base module...

Page 3: ...base module in locations That are behind a chimney Where temperature could exceed 150 F Where rain or snow or extreme hot or cold is possible Note This base module is NOT weatherproof Wireless Communi...

Page 4: ...erminal block can keep the thermostat from fitting on the subbase correctly or cause system operation issues Installation Tip Max Torque 6in lbs Wiring If you are replacing a thermostat make note of t...

Page 5: ...compressor run time to OFF 3 4 or 5 minutes If 3 4 or 5 is selected the compressor will run for at least the selected time before turning off Minimum Compressor OnTime OFF You can adjust the room temp...

Page 6: ...up Steps Adjustment Options Default LCDWillShow You can configure the thermostat to operate a 3 stage heat pump system 2H 2C 2 heat 2 cool 3H 2C 3 heat 2 cool This feature is shown only if the HEAT PU...

Page 7: ...OR FINDING SENSOR Disable the sensor on the master At least one indoor remote sensor must be connected to disable the local sensor LocalTemp Sensor YES enables local sensor NO disables local sensor YE...

Page 8: ...d Humidity Key Target humidity setpoint keys Note The target humidity setpoint is not programmable Unlike temperature humidity does not change quickly and should not be programmed Note Humidity is onl...

Page 9: ...are now programming the OCCUPIED time period for that day 4 Use the or key to make your time selection for the OCCUPIED time period Note If you want the fan to run continu ously during this time peri...

Page 10: ...customize your 7 day Program schedule follow these steps Monday Repeat steps 4 through 6 for the remaining days of the week A Note About Auto Changeover In Auto you have the ability to switch between...