Wiring 

Reestablishing Communication

Establishing communication between master thermostat 

and the base module

The thermostat and base module come factory linked out of the box. 

If however, communication is lost, follow this easy- two step process to 

re-establish the communication link.
1. Press and hold the base module 

button for 3 seconds. The Blue LED 

will flash when ready to receive 

initial signal from the thermostat. 

(Base module must be powered by 

24V. Blue LED will be continuously 

on when 24V power is present.)

2. Hold the light key (shown here) 

of the thermostat for 10 seconds, 

the Blue LED on the base module 

will stop flashing after 

communication has been 

established between base module 

and the thermostat.

Step 1.

LED Relay Indicators

Blue LED

Base Module Button

Note: 

The blue LED on the base module 

will be on when power is present. The blue 

LED will flash 3 times everytime it 

recieves a signal from the thermostat. 

When a relay is on the corresponding LED 

relay indicator will be on.

Step 2.

Light key

Note: 

If the base module does not 

receive a signal from the thermostat for 

15 minutes it will turn off all relays until 

communication is reestablished. The blue 

LED base module will also turn off to show 

communication has been lost.

Note:

 

If communication has been lost for 

1 hour and if freeze protection is enabled, 

heat and emergency heat relays will be 

turned on. The heat and emergency relays 

will turn on for 10 minutes every hour if 

there has been a call for heat in the last 24 

hours.

Important:

 

DO NOT hold the light 

button on the thermostat for more 

than 10 seconds after step 2 above 

has been completed. Holding the 

light button down will break the 

communication link and the base 

module button will need to be

pressed again to reestablish 

communication.

Wiring

Wiring

Caution: 

Electrical Hazard

All components of the 

control system and the 

thermostat installation must 

conform to Class II circuits 

per the NEC Code.

Warning:

Do not overtighten 

terminal block screws, 

as this can damage the 

terminal block.  A 

damaged terminal block 

can keep the thermostat 

from fitting on the 

subbase correctly or 

cause system operation 

issues.

Installation Tip

Max Torque = 6in-lbs.

Wiring

If you are replacing a thermostat, 

make note of the terminal 

connections on the thermostat that 

is being replaced.  In some cases 

the wiring connections will not be 

color coded. For example, the 

green wire may not be connected 

to the 

G

 terminal.

Loosen the terminal block screws. 

Insert wires then retighten the 

terminal block screws.

Place nonflammable insulation into 

the wall opening to prevent drafts.

1.

2.

3.

Wiring Tips

C Terminal

The C (common wire) terminal does 

not have to be connected when the 

thermostat is powered by batteries.

Wire Specifications

Use shielded or non-shielded 18-22 

gauge thermostat wire.

Failure to disconnect the power 

before beginning to install this 

product can cause electrical shock 

or equipment damage.

Note:

In many heat pump systems with 

no emergency heat relay, a jumper 

can be installed between 

E

 and 

W2

 to turn thermostat into a single 

stage control for Emergency Heat 

Operation.

Typical 2H/2C System: 2 Transformer

REMOVE JUMPER 

RC
RH

Y
C

W/E

G

W2

Y2

C

R

L2

L1

(HOT)

C

R

L2

L1

(HOT)

COMPRESSOR

RELAY

HEAT RELAY

FAN RELAY

HEAT RELAY 2

COMPRESSOR

RELAY 2

Power supply
Factory-installed jumper.  Remove only when installing on 2-transformer systems

Use either O or B terminals for changeover valve
If DEHUM relay requires a normally-energized input, set dehumidity relay to NC in 

technician setup.

 

Typical 2H/2C system with dehum terminal 

COMPRESSOR

RELAY

FAN RELAY

HEAT RELAY 2

COMPRESSOR

RELAY 2

HEAT RELAY

DEHUM RELAY

RC
RH

Y
C

W/E

G

W2

Y2

D

C

R

L2

L1

(HOT)

Power supply
Factory-installed jumper.  Remove only when installing on 2-transformer systems

Use either O or B terminals for changeover valve
If DEHUM relay requires a normally-energized input, set dehumidity relay to NC in 

technician setup.

 

RC

RH

Y
C

W/E

G

W2

Y2

H

COMPRESSOR

RELAY

FAN RELAY

HEAT RELAY 2

COMPRESSOR

RELAY 2

HEAT RELAY

HUMIDIFIER

Typical 2H/2C System with 24VAC Humidifier

C

R

L2
L1

(HOT)

COMPRESSOR

RELAY

FAN RELAY

HEAT RELAY 2

COMPRESSOR

RELAY 2

HEAT RELAY

24V RELAY 

NORMALLY-OPEN

TERMINALS

RC

RH

Y
C

W/E

G

W2

Y2

H

DRY CONTACT

HUMIDIFIER

HUM

HUM

C

R

L2
L1

(HOT)

Typical 2H/2C System with dry contact humidifier

Temperature

Summary of Contents for TP-S-955WH

Page 1: ...ctable wireless communication options Each component has a jumper switch label FSK and ASK Default setting FSK All components must be set to the same position for wireless communication Both modes uti...

Page 2: ...cal Mount Horizontal Mount For horizontal mount put one screw on the left and one screw on the right For vertical mount put one screw on the top and one screw on the bottom To connect the base module...

Page 3: ...base module in locations That are behind a chimney Where temperature could exceed 150 F Where rain or snow or extreme hot or cold is possible Note This base module is NOT weatherproof Wireless Communi...

Page 4: ...erminal block can keep the thermostat from fitting on the subbase correctly or cause system operation issues Installation Tip Max Torque 6in lbs Wiring If you are replacing a thermostat make note of t...

Page 5: ...compressor run time to OFF 3 4 or 5 minutes If 3 4 or 5 is selected the compressor will run for at least the selected time before turning off Minimum Compressor OnTime OFF You can adjust the room temp...

Page 6: ...up Steps Adjustment Options Default LCDWillShow You can configure the thermostat to operate a 3 stage heat pump system 2H 2C 2 heat 2 cool 3H 2C 3 heat 2 cool This feature is shown only if the HEAT PU...

Page 7: ...OR FINDING SENSOR Disable the sensor on the master At least one indoor remote sensor must be connected to disable the local sensor LocalTemp Sensor YES enables local sensor NO disables local sensor YE...

Page 8: ...d Humidity Key Target humidity setpoint keys Note The target humidity setpoint is not programmable Unlike temperature humidity does not change quickly and should not be programmed Note Humidity is onl...

Page 9: ...are now programming the OCCUPIED time period for that day 4 Use the or key to make your time selection for the OCCUPIED time period Note If you want the fan to run continu ously during this time peri...

Page 10: ...customize your 7 day Program schedule follow these steps Monday Repeat steps 4 through 6 for the remaining days of the week A Note About Auto Changeover In Auto you have the ability to switch between...

Reviews: