OmniFlow 330
6.3 C-1 top cover open
When the top cover is opened, it will come up C-1. If the flag didn’t press the
switch or the switch broken, it will come up the C-1 as well.
6.4 E-1elevator error
(
1
)
When feeding table gets stuck at the bottom, we can restart the machine. Then
press the start button and reset button at the same time.
(
2
)
When feeding table gets stuck on the top, we can restart the machine. Then
press the stop button and reset button at the same time.
6.5 C-6 Double or multiple feed
(
1
)
The machine didn’t have double feed detecting sensors on it.
(
2
)
Adjust the knob or blower by flowing the instructions in section 5.1.1 and
5.1.2.
Flag
Top cover switch
①
Reset button
16