Delta Elec. Inc.
Vivitek
rev.00
Company Confidential VIVITEK_______________________ Delta____________
68
2008/07/28
6. The function of lens mount adjustment
7. Adjustment Procedure
a. Move projection lens to be at center position of DMD
b. Rotate fixed screw counterclockwise around 15 to 30 degree (loosen it)
c. Adjust the image adjustment screw to make image on screen from corner position
to center position to be clear
d. Tighten the fixed screw
Projector
Screw for
adjustment
Screen
Image
curvature