4
Power LED
Lamp LED
/+
-%.5
).054
0/7%2
ß
6/,
#(
!$*534
!$*534
%8)4
,!-0
34!453
Normal Operation
States
Power LED
Lamp LED
Status Description
AC off
Not lit
Not lit
AC power not connected
Standby mode
Orange
Not lit
AC power is connected and your RPTV is in
standby mode.
Warm-up/Cool down
Blue
Flashing
AC power is connected and the power button has
just been turned on or off.
Operation mode
Blue
Not lit
AC power is connected, the power button has
been pressed, and the lamp has warmed up
Error Codes
States
Power LED
Lamp LED
Status Description
21
Flashes blue twice,
then orange once
Not lit
One of the cooling fans has failed. Call Service
Center to help you solve the question.
32
Flashes blue three
times, then orange
twice.
Flashing
Lamp trouble or failure. Your RPTV automatically
shut down and restart itself. If this does not solve
the problem, Call Service Center to help you solve
the question.
52
Flashes blue five
times, then orange
twice.
Flashing
Hardware error. Shut off your RPTV, wait one
minute, then restart your RPTV. If this does not
solve the problem,Call Service Center to help you
solve the question.
13
LED Status
There are two status LEDs on the front of your Micro Chip
Display Projection RP TV.
You may obtain the display’s related status through the LED