background image

3

To enter the custom programming menu, press and hold “M” and “T” together for 5 seconds. The controller will 

beep once and the display will begin flashing “62.0”. If no action is taken for more than 8 seconds, the controller 

will automatically exit the menu. Unsaved settings may be canceled by pressing “T”. The following instructions 

assume the controller is in the flashing “62.0” state.

Minimum & Maximum Height Settings

To set a minimum height limit

1. Press the up or down arrow to set your desired min. height.

2. Press “1” to save. “L-S” will be displayed if successfully saved, or “L-F” shows if failed.

Note: Default min. height is 62cm (24.4”), and the adjustable range is 62-118cm (24.4”~46.4”).

To set a maximum height limit

1. Press “M” repeatedly until “128” is displayed.

2. Press the up or down arrow to set your desired max. height.

3. Press “1” to save. “H-S” will be displayed if successfully saved, or “H-F” shows if failed.

Note: Default max. height is 128cm (50.4”), and the adjustable range is 72-128cm (28.3”~50.4”).

Adjust the Anti-Collision Sensitivity (Current Sensor)

To set collision sensitivity for upward movement

1. Press “M” repeatedly until “CC3” is displayed.

2. Press the up or down arrow to change the sensitivity level.

3. Press “1” to save. “S-S” will be displayed if successfully saved, or “S-F” shows if failed.

Note: Default sensitivity is 3, and the adjustable range is 0-5. (0: off, 5: maximum)

To set collision sensitivity for the gyro sensor

1. Press “M” repeatedly until “SC3” is displayed.

2. Press the up or down arrow to change the sensitivity level.

3. Press “M” to save. “S-S” will be displayed if successfully saved, or “S-F” shows if failed.

Note: Default sensitivity is 3, and the adjustable range is 0-5. (0: off, 5: maximum).

Displayed Height with Desktop Thickness

1. Press “M” repeatedly until “t0.0” is displayed.

2. Press the up or down arrow to set the desktop thickness.

3. Press “M” to save. “T-S” will be displayed if successfully saved, or “T-F” shows if failed.

Screen Lock Setting

1. Press “M” repeatedly until “A-1” is displayed.

2. Press the up or down arrow to change the screen lock setting. (0: off, 1: on)

3. Press “M” to save. “A-S” will be displayed if successfully saved, or “A-F” shows if failed.

When screen lock is enabled, the display will read "- - -" after resting 60 seconds.  Press and hold "M" for 3 seconds 

to unlock.  Screen may be locked before 60 seconds by holding "M" again for 3 seconds.

NOTE: “T-0” may also flash as you scroll through the menu options with “M”.  This is for a fatigue test and 

should not be adjusted.

Overload  

 

Desk running in reverse 

 

 

Uneven leg height  

 

Motor not connected 

 

Collision detected  

 

Control panel connection error  

Uneven desktop  

 

Short circuit    

Reset failure    

 

Abnormal electrical current   

 

Incomplete reset  

 

Memory function failure  

 

 

Collision sensor failure   

Remove excess weight from the desk

Replace motor cables

Reset the desk and ensure weight is evenly distributed

Check connection to control unit, replace cord if necessary

Release button and clear obstructions

Check the connection then reconnect desk power

Wait for self recovery

Replace the control unit

Check and replace the columns

Replace the control unit

Reset the desk

Replace the control unit 

Replace the control unit

Summary of Contents for DESK-V133E Controller

Page 1: ...le device or follow the link for helpful videos and specifications related to this product https vivo us com products desk v133e SKU DESK V133E Controller help vivo us com www vivo us com 309 278 5303 Chat live with an agent GET IN TOUCH Monday Friday from 7 00am 7 00pm CST ...

Page 2: ...t in memory Each number can store a different height Once in memory you can recall any of the three height settings by pressing the corresponding button Touching any button except for T will stop the automatic adjustment Changing between CM and INCH The preset measurement shown on the display is cm If you would like to change cm to inch then press T for at least 3 seconds The controller will beep ...

Page 3: ...r down arrow to change the sensitivity level 3 Press M to save S S will be displayed if successfully saved or S F shows if failed Note Default sensitivity is 3 and the adjustable range is 0 5 0 off 5 maximum Displayed Height with Desktop Thickness 1 Press M repeatedly until t0 0 is displayed 2 Press the up or down arrow to set the desktop thickness 3 Press M to save T S will be displayed if succes...

Page 4: ...sure you have a fully functioning product FOR MORE VIVO PRODUCTS CHECK OUT OUR WEBSITE AT www vivo us com help vivo us com AVG RESPONSE TIME within office hrs 1HR 8M 23 within 15m 38 within 30m 61 within 1hr 83 within 2hr 92 within 3hr Love your new VIVO setup and want to share Tag us in your photo vivo_us AVG RESOLUTION TIME within office hrs 15 M www vivo us com Chat live with an agent AVG RESOL...

Reviews: