- It is recommended that a minimum length of piping, equivalent to 10 pipe diameters, be used between the pump suction inlet

and any plumbing fittings.

WARNING –

Hazardous Pressure.

Pumps, filters, and other equipment/ components of a swimming pool filtration system operate under pressure. Incorrectly installed
and/or improperly tested filtration equipment and/or components may fail resulting in injury and/or property damage.

Plumbing

Use

Teflon tape

to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly cleaned

before use.

NOTE - Do NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic components.

When applying

Teflon tape

to plastic threads, wrap the entire threaded portion of the male fitting with one to two layers of tape. Wind the tape

clockwise as you face the open end of the fitting, beginning at the end of the fitting. The pump suction and outlet ports have
molded-in thread stops.

Do NOT attempt to force hose connector fitting past this stop.

It is only necessary to tighten fittings

enough to prevent leakage. Tighten fitting by hand and then use a tool to engage fitting an additional 1 ½ turns. Use care when using
Teflon tape as friction is reduced considerably;

do NOT over-tighten fitting or you may cause damage

. If leaks occur, remove

connector, clean off old Teflon tape, re-wrap with one to two additional layers of Teflon tape, and re-install connector.

Fittings

Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets). Avoid fittings that could
cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials
(IAPMO) standards. Use a non-entrapping suction fitting in pool (multiple drains) or double suction (skimmer and main drain).

Electrical

WARNING –

Ground and bond motor before connecting to electrical power supply. Failure to ground and bond pump motor

can cause serious or fatal electrical shock hazard.

WARNING –

Do NOT ground to a gas supply line.

WARNING –

To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.

WARNING –

Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. If GFCI trips and won’t reset,

consult electrician to inspect and repair electrical system.

WARNING –

Fire Hazard.

Match supply voltage to motor nameplate voltage.
Ensure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the
H.P. (KW) rating and distance from the power source.

NOTE - All electrical wiring MUST be performed by a licensed electrician,

and MUST conform to local codes and NEC regulations.

Use copper conductors only.

Max Rate

Full Rate

60 Hz,1 PH

HP

1

1

2

2

3

1-1/2

1-1/2

2-1/2

2-1/2

0.75

0.75

0.37

208-230

115

14 AWG

14 AWG
14 AWG

14 AWG
14 AWG

12 AWG

12 AWG

12 AWG

14 AWG

10 AWG

10A

15A
10A

15A
15A

20A

20A

20A

15A

30A

208-230

115

208-230

208-230

208-230

115

208-230

115

0.55

1/2

3/4

1.10

1.10

1.55

1.87

1.55

1.87

2.20

KW

HP

KW

Voltage

Amps

Wire Size

Summary of Contents for VH514

Page 1: ...USER S MANUAL 2 0 HP Swimming Pool Pump SKU VH514 THIS INSTRUCTION BOOKLET CANTAINS IMPORTANT SAFETY INFORMATION PLEASE READ AND KEEP FOR FUTURE REFERENCE ...

Page 2: ...not flood when it rains It requires free circulation of air for cooling Do not install in a damp or on ventilated location If installed within an outer enclosure or beneath the skirt of a hot tub or spa adequate ventilation and free circulation of air must be provided to prevent overheating of the motor WARNING Pool and spa components have a finite life All components should be inspected frequentl...

Page 3: ... of two functioning suction outlets per pump must be installed Suction outlets in the same plane i e floor or wall must be installed a minimum of three feet 3 0 91 meter apart as measured from near point to near point Dual suction fittings shall be placed in such locations and distances to avoid dual blockage by a user Dual suction fittings shall not be located on seating areas or on the backrest ...

Page 4: ... product should be installed and serviced only by a qualified professional Pump Location Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction loss Suction lines should have continuous slope upward from lowest point in line Joints must be tight but not over tightened Suction line diameter must equal or be larger than the discharge line diameter Th...

Page 5: ...ings Fittings restrict flow For better efficiency use the fewest possible fittings but at least two suction outlets Avoid fittings that could cause an air trap Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials IAPMO standards Use a non entrapping suction fitting in pool multiple drains or double suction skimmer and main drain Electrical WARNIN...

Page 6: ...d circuit breaker sizes Use the load circuit breaker as the Master On Off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufacturer s instructions In case of a power outage check GFCI for tripping which will prevent n...

Page 7: ... suction and discharge valves are open when pump is running See Troubleshooting Guide ATTENTION Wait five 5 seconds before re starting pump Failure to do so may cause reverse rotation of motor and consequent serious pump damage Close filter manual air relief valve after pump is primed Maintenance Clean strainer basket regularly Do NOT strike basket to clean Inspect strainer cover gasket regularly ...

Page 8: ...UCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When servicing electrical equipment basic safety precautions should always be observed including the following Failure to follow instructions may result in injury A WARNING To reduce risk of injury do not permit children to use this product B Disconnect all electrical power service to pump before beginning shaft seal replacement C Only qualified pers...

Page 9: ... 1 5HP 110 120V 220 240V 60 10 5 5 2 95GPM HAP1500II 1500W 2 0HP 110 120V 220 240V 60 12 5 6 25 103GPM TECHNICAL DATA FOR HBP POOL PUMP Model Power Voltage Hertz Amps Flow Rate HBP550 550W 0 7HP 110 120V 60 6 4 87GPM HBP750 750W 1 0HP 110 120V 60 7 3 93GPM HBP1100 1100W 1 5HP 110 120V 60 9 1 101GPM HBP1500 1500W 2 0HP 110 120V 60 12 5 110GPM HBP550I 550W 0 7HP 220V 60 2 9 79GPM HBP750I 750W 1 0HP ...

Page 10: ... Description 1 Lid 2 O Ring 3 Basket 4 Strainer 5 Drain plug 6 O Ring 7 Pump Body 8 O Ring 9 Screw 10 Flower mat 11 Diffuser 12 O ring 13 Impeller 14 Mechanical Seal 15 Bracket cover 16 Against hydrosphere 17 Motor 18 Earthing Terminal ...

Page 11: ...tion 1 Lid 2 O Ring 3 Basket 4 Drain plug 5 O Ring 6 Pump body 7 Nut 8 O Ring 9 Diffuser 10 Impeller 11 Mechanical seal 12 O Ring 13 Bracket cover 14 Flat Mat 15 Spring washer 16 Screw 17 Plastic basement 18 Support 19 Motor 20 Earthing Terminal ...

Page 12: ...k in the suction piping may be the cause b If pump does not develop a vacuum and pump has sufficient priming water i Re check strainer housing cover and all threaded connections for suction leaks Check if all hose clamps are tight ii Check voltage to ensure that the motor is rotating at full RPM s iii Open housing cover and check clogging or obstruction in suction Check impeller for debris iv Remo...

Page 13: ...roducts VIVOHOME reserves the right to modify this information without prior notification Please contact customer service via support vivo home com with any questions comments or concerns Thank you for using VIVOHOME products in your home ...

Reviews: