- 84 -
www.vivotek.com
(get/set)
name
string[40]
6/6
The identification of this entry
enable
0, 1
6/6
To enable or disable this event.
priority
0, 1, 2
6/6
Indicate the priority of this event.
“0” indicates low priority.
“1” indicates normal priority.
“2” indicates high priority.
delay
1~999
6/6
Delay seconds before detect next
event.
trigger boot,
di,
motion,
seq,
6/6
Indicate the trigger condition.
“boot” indicates system boot.
“di” indicates digital input.
“motion” indicates video motion
detection.
“seq” indicates periodic condition.
di
<integer>
6/6
Indicate which di detected.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin
<integer> 6/6
Indicate which motion detection
windows detected.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
inter
1~999
6/6
Interval of period snapshot in minute.
This field is used when trigger
condition is “seq”.
User's Manual - 93
VIVOTEK - A Leading Provider of Multimedia Communication Solutions