VIVOTEK
178 - User's Manual
driver.
2: enable PTZ commands with UART
tunnel.
disablemdonptz
<boolean>
0
1/4
Disable motion detection on PTZ
operation.
7.24 UART control (Not used in FE8174/FE8173/FE8181)
Group:
uart
(capability.nuart > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40] <product
dependent>
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
< product
dependent>
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
0
4/4
Enable HTTP tunnel channel to
control UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability.nuart > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
9600
4/4
Set baud rate of COM port.
databit 5,6,7,8
6,7,8
<product
dependent>
8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
none
4/4
For error checking.
stopbit
1,2
1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode
rs485,
rs485
4/4
RS485 or RS232.