EN |
2
EN |
3
The VIVREAU Extra series
The VIVREAU Extra product range in-
cludes the VIVREAU Extra 85 with a
cooling capacity of 85l/h (22.5 gal/h).
The system provides ambient still,
chilled still and chilled sparkling water
(medium and classic).
ThermalGate
™
The outlet of typical water systems is
usually completely unprotected and
exposed to the environment. Germs
settle on the wet water tap, and without
appropriate mechanisms this may lead
to a retrograde contamination.
The ThermalGate
™
protects from con-
tamination through external influences.
The outlet tap will be automatically
heated up at intervals and therefore
thermally disinfected.
VIVREAU HygienePlus
VIVREAU HygienePlus is a proprietary
3 zone protection system, only availa-
ble from VIVREAU. It is designed for
environments where hygiene is of the
utmost importance, and consists of
three key elements:
1. The inlet water filter includes pre-fil-
ter, activated carbon and membrane
technologies. The filter reliably
retains tested bacteria (acc. AST-
MF-838) and other health-hazardous
contaminants, such as cysts (in
line with NSF 53). It also improves
the taste of water by lowering the
amount of chlorine.
2. The VIVREAU CLARITY X3 filter
– located directly upstream of the
outlet tap – contains a very fine,
asymmetric double-layer membrane
that retains 99.99999% of remaining
bacteria (acc. to ASTM F838) and
99.95% of cysts (acc. to NSF 53)
before the water is dispensed.
3. VIVREAU’s ThermalGate
™
feature
automatically heats the outlet tap
at regular intervals. This protects
against retrograde contamination
from external sources, such as
physical contact (e.g. touching the
tap) and droplets (e.g. from sneezing
or coughing).
This instruction manual is valid for the following products:
VIVREAU Extra 85
(VIV E 85 I-33-C2-TG-J
VIV E 85 I-26-C2-TG-J)
VIVREAU Extra 85 HygienePlus
(VIV E 85 I-33-C2-HP-J
VIV E 85 I-26-C2-HP-J)
If a drain is not available only a VIVREAU waste container can be used.
GENERAL INFORMATION VIVREAU EXTRA