MAINTENANCE 

  Make sure that electrical and fitting connections are regularly inspected, cleaned and tightened when needed. 

  Make sure mounting screws are regularly tightened if needed. 

  Drain weekly, to avoid excessive buildup of condensation. 

  Compressor features a washable air filter which should be cleaned using any mild form of liquid soap every 

two months if it gets dusty. Just remove the front cover of the filter’s housing to reach it. Replacement time 
frames depend on the operating environment and how often it is used. 

  Clean dirt and dust from heat spreader and motor housing of the compressor. 

 

The motor of the air compressor has a maintenance-free lasting lubricant. 

DO NOT LUBRICATE

.

 

 

WATER TRAP 

 

DISASSEMBLY 

o

 

Filter can be disassembled without removal from air line. 

o

 

Shut OFF inlet pressure. Reduce pressure in inlet and outlet lines to zero. 

o

 

Remove bowl. Push into body and turn counterclockwise. 

 

CLEANING 

o

 

Clean bowl with warm water only. Clean other parts with warm water and soap. 

o

 

Rinse and dry parts. Blow out internal passages in body with clean, dry, compressed air. Blow air 
through filter element from inside to outside to remove surface contaminants. 

 

ASSEMBLY 

o

 

To assembly push bowl into body and turn fully clockwise.

 

SOLUTIONS TO COMMON ISSUES 

Issue: Compressor inoperable. 

Solution 1: Check all switches to make sure they are ON. 
Solution 2: Check the fuse; if blown, disconnect compressor from power and replace the fuse. 
Solution 3: Allow compressor to cool off for 30-60 minutes. 
Solution 4: Check pressure switch, replace if damaged or inoperable. 

 
Issue: Excessive moisture on suspension valves or safety valve. 

Solution 1: Depressurize and drain the tank. 
Solution 2: Relocate the compressor to a drier location. 

 
Issue: Continual cutting-off of Thermal overload protection. 

Solution 1: Relocate the compressor to a drier, cooler location. 
Solution 2: Replace the compressor. 

 
Issue: Excessive vibration or noise 

Solution 1: Tighten system components. 
Solution 2: Replace the compressor.  

 
Issue: Loss of pressure of tank when compressor is shut off. 

Solution 1: Tighten drain cock. 
Solution 2: Examine the check valve and replace if damaged or leaking. 
Solution 3: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 
Solution 4: Replace safety valve if present in the tank, it may be defective. 

 
Issue: Compressor runs continuously and has low air flow. 

Solution 1: Decrease the frequency of use. 
Solution 2: Use soap and water solution on air connections, and tighten connections or repair leaks where needed. 
Solution 3: Clean or replace the air filter element if it is clogged.  
Solution 4: Replace compressor. 

Summary of Contents for VXO4841DBF

Page 1: ...essor with bare hands as it is very hot during such periods Avoid use of product near flames explosive materials aerosol products or oxygen devices Be sure to pump nothing other than atmospheric air It is important to determine the maximum air pressure for any tool or attachment before using it Air sprayer or nozzle should always be pointed away from any part of the body The compressor has Thermal...

Page 2: ...ess steel braided hose of the compressor to the tank s inlet port For details about installing the water trap on the compressor line see water trap section below IMPORTANT The tank s inlet port must be 3 8 N P T National Pipe Thread REMOTE AIR FILTER INSTALLATION KIT Only use if you need to move compressor s air intake to an area other than where the compressor was installed A Braided Hose Bracket...

Page 3: ...tank s pressure until it ranges from approximately 5 PSI to 20 PSI Remove the drain valve found at the tank s bottom to drain the water from the tank After draining the accumulated condensation reinstall the drain valve IMPORTANT Draining the system regularly will extend the life of the air tank WATER TRAP INSTALLATION Start installation with the bowl detached from the filter body Connect the stai...

Page 4: ...r or an accessory terminal on the fuse panel Make sure to use wire that is as heavy as the wire of the compressor Connect together PIN 30 of both relays and connect it to a constant power source using the provided 60A fuse Both compressors are now set for use and will turn on automatically when air pressure in the air tank falls When air pressure reaches maximum PSI they will turn off If compresso...

Page 5: ...wl into body and turn fully clockwise SOLUTIONS TO COMMON ISSUES Issue Compressor inoperable Solution 1 Check all switches to make sure they are ON Solution 2 Check the fuse if blown disconnect compressor from power and replace the fuse Solution 3 Allow compressor to cool off for 30 60 minutes Solution 4 Check pressure switch replace if damaged or inoperable Issue Excessive moisture on suspension ...

Reviews: