background image

 

 

VXO4852DBF 

INSTALLATION GUIDE

 
 

 

PAGE 4 of 5

 

 

ELECTRICAL CONNECTION 

COMPRESSOR 

  Red wire (positive) of the compressor is connected to 

PIN 87

 on the relay. 

IMPORTANT

: Make sure to use 

wire that is as heavy as the wire of the compressor 

  Black wire (negative) of the compressor and 

PIN 85

 of the relay are connected to ground. 

  Repeat above steps for the second compressor. 

  Connect together 

PIN 86

 of both relays and then connect it to one of the terminal of the pressure switch. 

Attach the remaining terminal of the pressure switch to a power source in the vehicle that only gets power 
when the vehicle’s ignition is on. Recommended connection points are: windshield wiper motor, blower motor 
or an accessory terminal on the fuse panel. Make sure to use wire that is as heavy as the wire of the 
compressor.  

  Connect together 

PIN 30

 of both relays and connect it to a constant power source using the provided 60A 

fuse. 

  Both compressors are now set for use and will turn on automatically when air pressure in the air tank falls. 

When air pressure reaches maximum PSI, they will turn off. If compressors fails to reach the maximum air 
pressure of the tank, which is the Pressure Switch's cut OFF pressure, check all air connections for leaks. 
While compressor are pumping, use soapy water or any bubble solution to perform this check. In case the 
leak remains after tightening, re-apply thread sealant. 

 

NOTE

: To makes installation fast, trouble free and professional, this kit comes with two Pre-wired Relay Plugs 

(one for each relay), they will attach to the relay only in one position. 

 

 

Reviews: