VXH1101
INSTALLATION GUIDE
PAGE 2 of 2
AIR LINE INSTALLATION
On one side of the
included ¼” OD air
line, attach the compression nut and
force the air line upon the male inlet
fitting which is found on the electric
solenoid valve.
Pass the brass nut through the inlet
fitting and fasten.
Take the air line’s other side and place
the compression nut of the air tank
fitting on it. Force the air line onto the
male fitting of the tank and then fasten
the compression nut.
WARNING
:
Avoid tying the brass nut too tight.
ELECTRICAL CONNECTIONS
Wire one of the solenoid valve’s leads to the positive (+) terminal of the battery or alternator.
WARNING
: We
highly recommend that you use a 10A fuse (not provided) to assure that the circuit remains safe and will not
be damaged by excess current.
Wire the other lead of the solenoid valve to one of the terminals on the horn button.
Ground the other terminal on the horn button by wiring it to bare metal.