background image

VZN T5 SERIES

5

P/N 1011066 Rev. G 12/13 

IMPORTANT SAFETY INFORMATION (continued)

Protect from becoming dry

If the membrane dries out, irreversible damage to the Ultra 

Filter membrane may result. Protect the filter from becoming 

dry by keeping it wet and sealed at all times.

Protect from freezing

If the Ultra Filter membrane freezes during operation or stor-

age, irreversible damage to the membrane and brittle cracking 

of the cartridge or housing may result.

Protect from direct sunlight or other UV sources

Avoid long-term exposure to direct sunlight or other UV  

sources. The Ultra Filter should be stored in a dark location.

Protect from high temperatures or abrupt variation in 

temperature

The maximum operating temperature is 100°F (38°C). Avoid 

abrupt variations in temperature. Any temperature variation 

should be made slowly.

Protect from rough handling or dropping

Mechanical damage, external breakage, and/or internal break-

age of the filter can result if the system is dropped or bumped. 

Handle with care at all times during transportation and instal-

lation.

Protect from organic solvents and concentrated acids

Prevent any and all contact of the membrane with strong sol-

vents, solvents containing chlorine, or concentrated acids. Do 

NOT use strong solvents or concentrated acids on any plastic 

parts of the filter system. Examples of some solvents to avoid: 

acetone, methyl acetate (nail polish remover); hexane (spot 

removers); turpentine, toluene (paint thinners); dry cleaning 

solutions, insecticides.

Protect from abrasive material

The membranes must be protected from abrasive materials 

like shavings left in a pipe. Abrasive materials in contact with 

the membrane can cause irreversible damage to the mem-

brane. All pipes must be flushed clean before installing the fil-

ter. All plastic parts of the filter system must be protected from 

sharp objects like knives, sand paper, or other tools. Cutting 

or nicking a plastic part can weaken it and cause a leak. Do 

NOT use abrasive cleansers on any plastic parts.

Protect from water hammer

The system must be protected from shock, pressure surges, 

or pulsation that may occur inside water pipes. Water ham-

mer occurs in pipes when a valve or faucet shuts quickly. 

Install a water hammer arrestor (pressure vessel containing 

compressed air separated from the water by a diaphragm) to 

reduce pressure shock.

CAUTION

This equipment is to be installed to comply with the 
basic plumbing code of the Building Officials and Code 
Administrators, Inc. (BOCA) and the Food Service 
Sanitation Manual of the Food and Drug Administration 
(FDA).

CAUTION

All electrical connections must be in accordance with 
local electrical codes and any other applicable codes.

A ground fault circuit interrupter (GFCI) must be 
installed on the circuit to this system.

When installed on metallic plumbing, a properly sized 
electrical bonding jumper must be installed across the 
inlet and outlet pipes serving this unit.

CAUTION

Water Flow Regulator Assemblies are NOT interchange-
able. Operating the system with the wrong Water Flow 
Regulator or without a regulator can damage the sys-
tem, cause personal injury, and voids the warranty!

Summary of Contents for VZN-421H-T5

Page 1: ...y NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction...

Page 2: ...nt or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage from moisture leaking int...

Page 3: ...olumn and have it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the rig...

Page 4: ...ll electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS...

Page 5: ...eaning solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can ca...

Page 6: ...08 50 60 VZN 441H T5 9700750 100 240 10 08 50 60 Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below N...

Page 7: ...ary NOTE The NSF WQA information provided applies to the Ultra Filter cartridge Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or aft...

Page 8: ...llecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE Do NOT unplug the power cord or turn off the sys tem during Flush Mode If there is a power outage or the system is...

Page 9: ...atch the appropriate outlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line...

Page 10: ...the system to the wall Some of the bottom mount INSTALLATION continued ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat...

Page 11: ...with an appropriate fitting not supplied Figure 3 3 Direct the other end of the hose to the drain Figure 3 When connecting the drain hose pay attention to the follow ing guidelines The drain line plum...

Page 12: ...gure 6 Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Filtered...

Page 13: ...and wait for five minutes to flush out any remaining air 12 Close the Rinse Ball Valve and disconnect the garden hose 13 Press the FLUSH button to open the Drain Valve Repeat six times to ensure any r...

Page 14: ...e system until the presence of sanitizer is gone 14 Open all other faucets and taps in line with the system to flush any remaining sanitizer from the plumbing 15 Close all faucets and taps Rinsing the...

Page 15: ...ght coating of lubricant to the inside cen ter tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer t...

Page 16: ...ining the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element...

Page 17: ...The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary 10 Direct water from the Rinse Ball Valve to drain NOTE It is important to direct the Rinse Ball Valve t...

Page 18: ...will also turn on Figure 12 Universal Pulse Controller Semi Annual Tasks Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Tools and suppli...

Page 19: ...replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Stora...

Page 20: ...SERIES 20 P N 1011066 Rev G 12 13 REPLACEMENT PARTS 30 36 37 33 25 25 1 2 39 3 31 12 28 20 14 14 29 16 32 38 14 15 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 24 35 9 8 10 10 34 VZN 421H T5 Sy...

Page 21: ...ES 21 P N 1011066 Rev G 12 13 30 33 25 1 2 3 31 34 12 20 16 32 14 15 19 4 5 6 7 8 9 11 17 21 13 18 20 21 22 23 24 9 8 10 10 36 37 25 28 14 14 29 26 27 24 35 39 38 REPLACEMENT PARTS continued VZN 441H...

Page 22: ...34 0505871 VZN Mounting Bracket 1 35 2190154 Adaptor 1 Stem 1 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 0021667 Flow Regulator Assy 7 9 gpm 1 39 0012146 Power Adapto...

Page 23: ...VZN T5 SERIES 23 P N 1011066 Rev G 12 13 NOTES...

Page 24: ...operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or...

Reviews: