Installation order:
Make holes for the armature plate and guide pin
Fix the armature plate on the inner side of the door, using fastening kit (Figure ).
Leave 4..5mm clearance between the plate and door surface.
the plate bar / angle bar on the door frame with screws (1) as on Figures
. Do not fasten the screws very tight, so
that you could further adjust the plate bar / angle bar position, if needed.
Fix the electromagnet on the plate bar / angle bar with screws (3)
Adjust the electromagnet with plate bar / angle bar to ensure the closest fitting of the electromagnet’s work surface to
the armature plate
Remove the electromagnet off the plate bar / angle bar.
Tighten the screws (1, 2) to securely fix the plate bar / angle bar on the door frame.
Fix the electromagnet on the plate bar / angle bar
Terminals of the lock have no polarity. The example of wiring diagram is given on Figure .
1.
.
2.
3.
Fix
4.
.
5.
.
6.
7.
8.
.
1
2, 3
CONNECTION AND FUNCTIONAL
5
CHECK
Note.
Use M6x45 screw for fixing the armature plate, if the door thickness ranges from 50 to 60 mm. M6x45 screw is not
supplied.
Requirements for wires and
more wiring examples are given in the controlling device operating instruction.
The controlling device can be a doorstation, control unit, TM- or RF-keys controller etc. Program
lock type in the
controlling device
electromagnetic and its unlocked state duration (if the functions are supported) following the
corresponding operating instruction. The lock is released when voltage across its terminals is off.
After installation and wiring complete, check all the connections.
Switch the power on. The electromagnet attracts the armature plate.
The door is locked. Check if locking is firm.
Perform unlocking according to the controlling device operating instruction.
Check if the electromagnet releases the armature plate.
the
as
,
,
,
,
2
3
1
Electromagnet
2
Plate bar
Figure
Lock mounting using plate bar
2 –
Figure
Lock mounting using angle bar
3 –
Figure
Armature plate mounting
1 –
Armature plate
Nut
Door leaf
Door frame
Screw
Spacer (not supplied, optional order)
Washer
Rubber washer
2
1
Angle bar
3
Electromagnet
Screw nut
www.
201 -
Operating Instruction VIZIT-ML300M-x (revision
6 06)
vizit.eu
2 3
/