Setting
Description
Adjustment
Default
Allow Low Battery
Restart
In Standby, allow the
engine to restart
based on low battery
level
Enabled/Disabled
Enabled
Battery Restart Lower
Threshold
Engine will restart if
below this threshold
for 30 seconds in
Standby
10.0
– 14.0V @ 0.1V
increments
12.1V
Battery Restart Upper
Threshold
System will start
duration timer if above
value
10.0
– 15.0V @ 0.1V
increments
12.8V
Battery Restart
Duration
Once above Upper
Threshold, stay
running for duration to
charge battery
1, 2, 5, 10, 15, 30
minutes
2 min