Loosely connect the hydraulic discharge and feed hoses to determine the
correct hose routings and fitting orientation (the inlet port on the hydraulic
pump is #12 ORB, the outlet port is #10 ORB).
☐
Remove the pump and tighten the hydraulic fittings.
☐
Apply Loctite 242 (blue) to the supplied fasteners and install the hydraulic pump.
Refer to the instructions included with the hydraulic pump for torque values
Figure 22 — Securing the hydraulic pump
When determining hydraulic hose routing, consider the relative
motion of the transmission, vehicle cab and front drive shaft (if
installed). Ensure the hoses are adequately protected and secured
away from any hot, sharp or moving parts.