Mounting Locations
Top Mounting
Top mounted, is the preferred mounting location. Placing the unit on top of
the service body provides the best access to cool fresh air. Maintain a
minimum of 6 in between the sides of the Gas Engine Driven 30 CFM Air
Compressor and 1 ft in front of the WHASP cooling fan and all other solid
objects (Figure 9).
When selecting a top mount location, ensure the fuel shut off
valve is easily accessible. The fuel valve must be shut off
when the unit is not in use, including during transport.
Enclosed Mounting
Enclosed mounting is not recommended due to the significant
heat generated by the unit. As the engine used on the Gas
Engine Driven 30 CFM Air Compressor is air cooled, special
consideration must be given to ensuring an adequate supply
of cool fresh air flows to the engine.
Mounting the Gas Engine Driven 30 CFM Air Compressor in an enclosure will
limit access to cool fresh air, restrict the escape of hot air from around the unit
and have an adverse effect on cooling, engine performance and reduce the
unit’s duty cycle. Ensure adequate ventilation is provided for cooling and to
evacuate the exhaust. If mounting in an enclosure, VMAC strongly
recommends mounting the unit on a pullout drawer and extending the drawer
any time the unit is run.
Figure 9
– Mounting locations
While it is not possible to make absolute recommendations regarding
ventilation due to the widely differing circumstances that are possible, duty
cycle, ambient temperature and enclosure shape are some of the important
variables that must be considered.
Ensure the engine exhaust and hot air generated by the gas
engine and WHASP Tank cooler are routed in such a way as to
prevent recirculation back into the unit.
Minimum considerations for mounting in an enclosure
Supply cool fresh air to:
Exhaust and heat:
•
Engine air intake.
•
Compressor air intake.
•
Compressor cooler.
•
Duct the engine exhaust outside of
the enclosure / vehicle.
•
Install an exhaust fan to remove
hot air from the enclosure.