VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289
Fax: 1-250-740-3201
13
Figure 2 - Unloader Valve (Shroud removed for clarity)
Hot Environment Operation
For operating in temperatures above 35 °C (90 °F) compressor use may
be limited. As the Gas Drive is a 100% duty cycle compressor high
ambient air temperatures may result in compressor overheat.
The compressor system is protected by a compressor oil temperature
switch that opens at 143 °C (290 °F) and disables the engine. The
cooling fan will operate anytime the key switch is in the run position.
If the gas drive shuts off due to overheat allow the system to cool before
restarting.
For engine oil recommendations in temperatures above 35 °C (90 °F)
refer to the
“Subaru Engine Manual” supplied with the system. (VMAC
part number: 1901022). Not following the
“Subaru Engine Manual"
supplied can result in poor engine performance or engine damage.
Hot Environment Recommendations:
Adequate supply of cool ambient air to the unit.
Exhaust and hot air can vent from the system with no
restrictions.
WHASP radiator fins and engine recoil start are clear of debris.
Install an external fan to direct cool air towards the engine and
air compressor.
Engine and compressor serviced at correct intervals.
Summary of Contents for RAPTAIR-G30
Page 1: ...RAPTAIR G30 Gas Drive Air Compressor Installation Owner s and Service Manual G300002...
Page 2: ......
Page 89: ...This page intentionally left blank...
Page 91: ...This page intentionally left blank...
Page 92: ...This page intentionally left blank...
Page 93: ...This page intentionally left blank...
Page 94: ...This page intentionally left blank...
Page 95: ......
Page 96: ......