20
Ventilation Requirements
Proper ventilation is vital for proper operation and
safety. When a system is not properly cooled it can
lead to oil deterioration, increased oil consumption,
power loss and reduced life or failure of the engine or
compressor.
Compressor overheat will disable the engine.
During operation, the Gas Drive can develop considerable heat. As the
engine used on the Gas Drive is air cooled, special attention must be
taken to ensure adequate air flow to the engine.
Ensure there is a minimum of 6 in (150mm) clearance between engine
air intake (recoil starter area) and the WHASP cooler and any other
components mounted on the vehicle. Direct the engine exhaust to vent
to atmosphere and in a safe location (Figure 9).
Figure 9 - Airflow diagram
Exhaust Extension
When adding an exhaust extension, ensure the following requirements
are met (Table 1):
Exhaust Pipe Length
Diameter
Exhaust pipe less than 10 feet (3 meters)
1.18 in (30 mm)
Exhaust pipe 10 ft (3 meters) to 16 ft (5 meters)
1.3 in (33 mm)
Table 1 - Exhaust Extension Diameter Table