7.2.1
Control System Terminology
System State: SYSTEM READY
Compressor system is ready for operation and awaiting a start
request. A start request can be made by:
Pressing ON/ENTER from the Display Box
Turning the key to the START position
Grounding the Remote Start wire
System State: GLOW PLUG
Sets the initial delay for the glow plugs based on engine temperature
(1 to 15 seconds).
The engine restart buzzer is enabled for 3 seconds then paused for 3
seconds before going into the next state to crank the engine. The
glow plugs are enabled during the buzzer cycle and during engine
cranking.
Temperature
Glow Plug Delay
Less than 20°C/68°F
15 seconds
Between 20°C/68°F
and 40°C/104°F
Linear extrapolation from 15 seconds to 1 second
Greater than 40°C/104°F
1 second
System State: STARTING
The control system will attempt to start the engine.
The control system will allow the engine to attempt to start for 20
seconds. If the engine fails to start the control system will flag a
starting error to the Display Box.
System State: WARMING
The control system will wait until the engine and compressor
temperatures are above 5°C/41°F before loading the compressor
system and going to the RUNNING state.