System State: UNLOAD
In UNLOAD mode, the control system will disable the compressor
clutch.
To return to the RUNNING state, the control system calculates the
air use rate of the air tool (PSI/second).
If the air use rate is above a preset value (HIGH AIR USE RATE) the
system will detect that an air tool is used and will switch states.
The system will also return to the RUNNING state if pressure is
below the Restart Pressure.
If the system continues to not detect air use, it will continue to count
down the delay to STANDBY timer.
If the Delay To STANDBY timer has finished counting down, the
system will go to STANDBY mode.
If the Genset or PTO switch is activated, the control system will not
go into STANDBY mode.