VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
35
TOP-UP PSI
This parameter allows tank pressure to be close to system pressure.
If pressure goes below SYSTEM PRESSURE minus TOP-UP PSI
(ie. 150PSI
– 10PSI = 140PSI) the inlet will open and fill to system
pressure and reset the idle timer.
HIGH AIR RATE
Air rate is a change in time of pressure (PSI/seconds) used to
monitor if an air-tool is being used. Setup of this parameter depends
on the air tool and tank size.
A small tank using a large tool will have a large air-rate, if the tank
size is increased the air rate will be lower.
This parameter allows a quick restart response when the system is in
STANDBY rather than reaching the restart pressure to restart the
system.
RESTART PRESSURE
This parameter is used to restart the system when pressure has
gone below the set value in STANDBY.
COLD ENGINE RESTART
This will allow the engine to restart if temperature has dropped below
a preset value in STANDBY.
DISABLE AUTO RESTART
Disable the engine from restarting in STANDBY after an adjustable
time.
ALLOW LOW BATTERY RESTART
Allow to restart the engine from STANDBY if the voltage threshold is
below BATTERY RESTART LOWER THRESHOLD for 30
continuous seconds.
BATTERY RESTART LOWER THRESHOLD
Low battery threshold for a restart request.
BATTERY RESTART UPPER THRESHOLD
After a low battery restart the system will stay in RUNNING until
battery voltage is above the upper voltage threshold to start the
BATTERY RESTART DELAY.
BATTERY RESTART DELAY
Delay to keep the idle timer reset so the battery will charge. A 2
minute delay is typical for a RAPTAIR battery, 5 minutes or greater
for additional batteries (ie. truck batteries).
Summary of Contents for RAPTAIR-MF D600007
Page 2: ......
Page 62: ...This page intentionally left blank...
Page 64: ...This page intentionally left blank...
Page 65: ...This page intentionally left blank...
Page 66: ...This page intentionally left blank...
Page 67: ......
Page 68: ......