VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
50
SCAVENGING
TUBE
DISCHARGE
FITTING
Figure 7 – Avoid Damaging the Scavenge Line
Check the filter to make sure that the threaded nipple did
not unscrew with the filter. If it is in the filter, remove it
carefully to avoid thread damage, coat the threads that
go into manifold block with a small amount of Loctite
blue and install it into the manifold block. Use caution
when removing the filter so as to avoid catching the
scavenge screen orifice on the bottom of the scavenge
tube on the lip of the coalescing filter. This scavenge
screen orifice is attached to the scavenge tube by a
“push to connect” fitting, if the fitting has come off of
the tube re-insert the tube into the fitting ensuring that
the tube is fully engaged.
Check the gasket-sealing surface of the manifold block for
contamination, old gasket material or damage.
Make sure the new filter is a VMAC filter, part # 3600079.
This is a high-pressure filter. Use of other filters not
rated to the required pressure may cause the filter to
rupture.
Apply a thin coating of compressor oil to the coalescing filter
sealing gasket and coat the end of the threaded nipple, as there
is also an O-ring inside the coalescing filter.