VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-800-738-8622 Local: 1-250-740-3200
Fax: 1-250-740-3201
44
VMAC certified synthetic oil should be used. Failure to
use this oil may result in damage to the compressor and
may void the warranty. Contact your nearest VMAC
dealer for oil or service kits. See our website
8.2
Checking and Adding Compressor Oil
8.2.1
Check oil level in air/oil separator tank
The air compressor system holds 4 litres of oil, which includes
enough to fill the oil filter. The filter holds 0.3 litres of oil. The
compressor holds about 0.5 litres of oil.
Check the level the oil has reached on the oil level sight glass.
MAX
ADD
UP
Sight Glass
Window
Drain Plug
VR70
Figure 4 – Checking Compressor Oil Level
Use a funnel inserted into the oil fill port on the air end (below the
coalescing filter).
Turn the compressor clutch clockwise as oil is poured into the
funnel until the oil is at the top of the sight glass.
Replace the cap on the oil fill port and tighten.
Start the system following the start-up procedure in section 7.3.1.
Allow the system to pressurize.
Turn off the system using the shutdown procedure in section
7.3.2.
Wait 5 minutes then drain the air fully to depressurize the
system.
Check for oil leaks.
Repeat until the oil level sight tube
shows the oil level in the
air/oil separator tank is in the operational range.