VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289 Local: 250-740-3200
Fax: 1-250-740-3201
10
1.5 Auxiliary Air Tank
If an auxiliary air tank is to be used with this system the
following setup MUST be followed. Failure to observe this
procedure will result in damage to the system.
1. The auxiliary air tank must be connected to the supply valve.
2. The air line MUST have a 60 psi minimum pressure check valve
(VMAC P/N # A700187) installed to prevent blow back from the
auxiliary air tank into the compressor system.
3. The air line MUST be connected as high as possible on the
auxiliary air tank.
4. The auxiliary air tank MUST have a pressure protection valve
calibrated for about 200 PSI (1379 kPa).
In stall 60 p si Min im u m
p ressu re ch eck valve
o n to su p p ly valve