Installation Instructions, 

Revised 02/11/14 

 

 

 

INSTALLATION INSTRUCTIONS & 

USE & CARE GUIDE 

08E W/P Series Models

 

 
 
 
 
 
 

 

 

Model 

Front Panel 

Dimensions 

08E W/P 

17-5/8

” x 45” 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
Before beginning installation, please thoroughly read and become familiar with these instructions.  Installation and 
service must be completed by a qualified installer.  Failure to properly install this product may void the warranty.

 

 

Installer:    Please leave Installation Instructions with the range hood liner. 

Owner:    Please keep Install

ation Instructions for local electrical inspector’s use and for future reference. 

 

 
 

 
 
 
 
 
 
 

WARNINGS:  

Must be followed carefully to avoid personal injury.

 

 
 

 
 
 
 
 
 
 

IMPORTANT:  

Must be followed carefully to avoid damage or incorrect installation. 

 
 

 
 
 
 
 
 
 

TIPS:  

Contain helpful information to facilitate installation. 

 

READ AND SAVE THESE INSTRUCTIONS 

 

 

WARNING!  TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO 

PERSONS OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.  If you have any questions, please contact the 
manufacturer at the address or telephone number listed in the warranty.  

 

b)  Before servicing or cleaning unit, switch power off at service panel and lock service panel and lock the service 
disconnection means to prevent power from being switch on accidentally.  When the service disconnecting means 
cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. 
 

 

CAUTION

 -- 

For general ventilating use only.  Do not use to exhaust hazardous or explosive materials 

and vapors. 

 

WARNING 

– TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 

 

a) Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may 
ignite.  Heat oils slowly on low or medium settings. 

 

b) Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambe’). 

 

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter. 

 

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element. 

Summary of Contents for Air-Pro 08E W/P

Page 1: ...in the manner intended by the manufacturer If you have any questions please contact the manufacturer at the address or telephone number listed in the warranty b Before servicing or cleaning unit swit...

Page 2: ...ct joints with high quality duct tape 4 Do not use this unit with any solid state speed control device 5 This unit must be grounded INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRI...

Page 3: ...oof cap location To get the best result use a minimum number of transitions and elbows Be sure to attach a roof wall cap to avoid rain from entering the exhaust duct The range hood unit should be moun...

Page 4: ...t hold up the front panel Hold the front panel in place as you loosen the screws so that the front panel does not fall onto the cook top When putting back on the front panel and aluminum knob DO NOT o...

Page 5: ...een the screwheads and wall for mounting the range hood Hook the temporary fixing holes of the hanging bracket on the washer head wood screws prepared in previous step and tighten the screws Note Inse...

Page 6: ...08E P Ceiling Mounting Put 4 all thread rods 1 2 anchor bolt not supplied into the corner holes of the mounting bracket and secure them using washers spring washers and nuts Place the mounting bracket...

Page 7: ...side is impossible remove the exhaust pipe unit and insert the duct end to the range hood directly then make inside taping on the duct end Be sure to attach a roof wall cap with damper in this case AC...

Page 8: ...imension 2 8 Round Duct Exhaust Direction Vertical Discharge from top Horizontal with Elbow Installation At 4 places on flange of body use screws and nut plates for mounting to Liner Wall mount with b...

Page 9: ...distort and damage the liner and void the warranty Always install ventilation products with an approved wall or roof cap Duct performance is improved by using round smooth metal duct work instead of...

Page 10: ...nd the fit is too tight simply remove one or more of the shims to get a proper fit Note All the mounting holes should be used to ensure adequate installation CONNECTING TO THE VENT PIPE The 08E W P se...

Page 11: ...ipe across the grain After cleaning reinstall the filters carefully HALOGEN LIGHT BULBS Blowers are designed for 50 watt MR16 GU10 Halogen Lamp They can be purchased at most home or grocery stores e g...

Page 12: ...Speed Wiring Details Black 120 volt AC from electrical panel usually black White Neutral from electrical panel white Green Ground from electrical panel usually green Wiring Diagram 08E W P Series Mod...

Page 13: ...nsistent with the recommended installation instructions Product used other than for normal in home use or products used outside of the United States and Canada Damage to the product caused by accident...