17
TECHNICAL SPECIFICATIONS VIBER X1™
INPUT SENSITIVITY:
100mV/g calibrated at 156.15 Hz.
MEASURING RANGE:
Velocity: 0-200 mm/s RMS
FREQUENCY RANGE:
Total level 2-3200 Hz
Adjustable
fi
lters: 2-10, 1000 - maximum
Hz
Bearing condition 500 Hz – 20 kHz
WEIGHT:
270 gram with accelerometer and
batteries
The measurement mainly follows
ISO10816-3.
ACCURACY*:
Better than +/- 3 %
* This value can be higher, close to the
fi
lters cut off frequency.
BATTERY TYPE:
3 pc of AAA Rechargeable
VIBRATION TRANSDUCER*
The accelerometer VMI 192 has a sensitivity 100mV/g +/-10%.
MAGNET SUPPORT
Length: 20mm, Diameter: 15mm, Magnet force: about 14kg
Note!
You must avoid to use other accelerometers bacause of the calibration.
If you change accelerometer the instrument must be calibrated to
preserve the accuracy.
Technical data VIBER X
.
You should avoid using other accelerometers
because of instrument calibration. If you
change the accelerometer, the instrument
must be calibrated to preserve the accuracy.
TM
Note 2. Wait until the instrument has stabilized
resonably well, before starting measurement.
Note 1.