Field Options Description
Master
Clocking calibration information is sent to
the peer based on an internal clock, which
can also be configured via the clocking menu
to driver GRX and/or GTX
Rate 0-4096000
or automatically
generated based on the IP
CIR
The effective bandwidth of the IP aggregate
that is available for multiplexing. This does
not include the overhead of IP headers.
When configured this Rate also determines
the value set for the IP CIR. If a value is
entered for Rate and then the user enters a
value for IP CIR (discarding the
automatically generated value) the Rate will
be re-calculated based on the IP CIR.
IP CIR
Automatically configured
based on the Rate
or
0-4096000
The committed information rate required
from the IP network to support this IP
aggregate. This does include the overhead of
IP headers, but can only be used when there
is a non-zero multiplexing overhead
configured.
The IP CIR is automatically calculated based
on the value entered for Rate. If a specific IP
CIR is entered (discarding the automatically
generated value), the Rate will be re-
calculated based on the IP CIR.