11.6.6 Reduce the domestic water flow rate to ap-
proximately 3-4 litres/min. Turn the domestic
control knob slowly to minimum the boiler
output will reduce to the minimum setting. If
low flame cannot be established in this way,
turn off the electricity supply, and disconnect
a grey wire from the modulator coil. Switch on
the electricity supply, the boiler will now light at
the minimum setting.
11.6.7 When low flame is established the pressure
reading should be :
Plus AG (LPG)
3.7 mbar
(Plus or minus 0.37 mbar)
If it is different adjustment should be made in
accordance with the instructions in 8.23.
11.6.8 If a grey wire was disconnected from the
modulator coil to check the minimum setting,
turn off the electricity supply and reconnect
the wire.
11.7 Maximum Rate in Central Heating Mode
The Linea range does not require any adjust-
ment to the maximum heat requirement of the
system load.
11.8 Setting the Minimum Rate for Central Heat-
ing
The Linea range does not require any adjust-
ment to the minimum heat requirement of the
system load.
11.9 Soft light ignition and range rating for central
heating is fully automatic, no adjustment is
necessary.
11.10 Turn mode selector to the OFF position, dis-
connect pressure gauge, re-tighten screw.
Relight boiler.
11.11 Re- check for gas soundness.
11.12 Replace electrical controls panel.
11.13 Refix the boiler casing (fig. 24).
11.14 Hinge up controls facia and secure using the
2 screws (fig. 25).