1) 

Insert a small straw or toothpick into the threaded inserts found on the back 

of the flat-panel.

2) 

Use a pencil to mark the depth of the threaded insert on the small straw or 

toothpick.

3) 

Mark the straw or toothpick 1/8” (3.175 mm) above the depth of the threaded 

insert, as shown in Figure 1.

4) 

Insert the small straw or toothpick into the remaining threaded inserts to 

compare and verify their depth using the straw or toothpick’s 1/8” (3.175 mm) 

allowance mark.

5) 

Locate the correct diameter screw for the threaded insert. 

  If the screw you selected is longer than the 1/8” (3.175 mm) allowance 

mark on the small straw or toothpick, as shown in Figure 2 and Figure 3, 

do not use this screw. The screw length must not bypass the mark.

6)   Test each size of the screws provided.  

         The correct screws should thread easily into themounting point and not pull 

out when tension is applied.

Small Straw or Toothpick

Marking the 1/8” 
Allowance

Small Straw  
or Toothpick

Small Straw  
or Toothpick

Depth Plus 1/8” Allowance
Mark

Depth Plus 1/8” Allowance
Mark

Selecting the Mounting Hardware

Securing the Adapters

Optional adapters are available with your PFW 6875 mount. 
Secure the adapters to the PFW 6875 brackets with the 
supplied M8 washers and Nuts. 

M8 Nylon

 

nut

M8 Washer

Page 7

Summary of Contents for PFW 6875

Page 1: ...PFW 6875 www vogels com Europe 31 0 40 26 47 400 Installation Guide Installationsanleitung Guía de Instalacíon Guida de Installazione Guide d Installation Installatie gids ...

Page 2: ...6 7 93 mm Concrete Wedge Anchors Qty 4 5 16 Flat Washers Qty 4 Universal Washers Qty 4 Pencil Protective Eyewear Electronic Stud Finder M6 or 1 4 Drill Bit M8 or 5 16 Concrete Drill Bit Portable Drill Phillips Head Screwdriver Socket Wrench 13mm or 1 2 Socket 10mm Socket Level M5 Allen Driver Qty 1 M4 x 12mm Qty 4 M4 x 16mm Qty 4 M4 x 25mm Qty 4 M6 x 12mm Qty 4 M6 x 16mm Qty 4 M6 x 25mm Qty 4 M8 x...

Page 3: ...se a pencil to mark each of the wall studs Wood Stud Installation Use a pencil to mark the upper right mounting location of the wall stud Drill a pilot hole using a M6 or 1 4 drill bit on the stud that was marked on the upper right 1 Place the mount against the wall and align it with the pilot hole 2 Insert one 1 5 16 x 3 76 mm lag bolt one 1 5 16 washer into the upper right pilot hole 3 Use a soc...

Page 4: ... 5 7 6 1 Level the mount 2 Use a pencil to mark the remaining three 3 mounting locations 1 Insert one 1 5 16 x 3 76 mm lag bolt and one 1 5 16 washer into each pilot hole 2 Tighten all lag bolts using a socket wrench and 13mm or 1 2 socket Do not over tighten the lag bolts Drill a pilot hole in each of the three 3 marks with a power drill and a M6 or 1 4 drill bit Page 4 ...

Page 5: ...rk areas with a M8 or 5 16 concrete drill bit 1 Place the mount against the wall over the threaded shafts of the concrete wedge anchors 2 Attach the nuts and washers you remove and add 1 5 16 washers on each threaded shafts 3 Tighten using a socket wrench and a 10mm socket Do not over tighten the concrete wedge anchor 1 Insert the concrete wedge anchors into each hole Lightly tap each concrete wed...

Page 6: ...are to secure the spacer to the wall during installation depending on the wall material You may utilize the same spacer for multiple PFW 6875 installations Start Multiple PFW 6875 mounts can be installed using model specific spacers Simply repeat step one when installing each of the surrounding PFW 6875 mounts Use one spacer for each 2x2 installation by mounting it to the wall or utilize the same ...

Page 7: ... mm allowance mark 5 Locate the correct diameter screw for the threaded insert If the screw you selected is longer than the 1 8 3 175 mm allowance mark on the small straw or toothpick as shown in Figure 2 and Figure 3 do not use this screw The screw length must not bypass the mark 6 Test each size of the screws provided The correct screws should thread easily into themounting point and not pull ou...

Page 8: ... mounting screw and the mounting bracket as shown Does your flat panel have Recessed mount points Uneven mount points A curved back Any obstruction near the mount point If Yes you must install Universal Spacers Remove the mounting brackets Universal Washers and mounting screws from the back of the flat panel Proceed to the Universal Spacer Installation section If No skip to the Attaching the Mount...

Page 9: ...nd bottom mounting rails on the wall panel 2 Slide the flat panel down slowly keeping it close to the wall 3 Engage the top and bottom mounting brackets to the rails of the mount Note These registers must align prior to installation They are factory set Check to determine proper alignment Attaching the Flat Panel to the Mount Page 9 1 Place your flat panel screen side down on a soft flat surface 2...

Page 10: ...king safety screws keep the flat panel from being accidently dislodged from the PFW 6875 1 Locate the pre installed security locking safety screw at the bottom of each of the mounting brackets 2 Use the M5 Allen driver supplied to tighten the locking safety screw Locking Safety Screw Installation Do not overtighten the locking safety screws Note Tighten screw to surface then tighten 1 4 6 35 mm tu...

Page 11: ...da de Installazione Guide d Installation Installatie gids www vogels com Europe 31 0 40 26 47 400 Tilt Left Left Control Right Control Tilt Right Left Control Right Control Tilt Up Left Control Right Control Tilt Down from tilted up position Left Control Right Control Page 11 ...

Page 12: ...e Installazione Guide d Installation Installatie gids www vogels com Europe 31 0 40 26 47 400 Level Up Left Control Right Control Level Down from leveled up position Left Control Right Control Rotate Left Left Control Right Control Rotate Right Left Control Right Control Page 12 ...

Page 13: ...r 050 1 27 mm gap adjust if needed Damage happens when weight is transferred to the ultra thin bezels of video wall installations if the recommended gap specifications of 050 1 27 mm is not maintained vertically and hori zontally This results in image distortion and costly repairs and replacement Use the GAPit GO No Go Gauge supplied with model specific spacer as a final step in the process to ins...

Page 14: ...ck Figure 1 2 Slowly pull the front of the PFW 6875 to extend the scissor arms Figure 2 3 Loosen the locking safety screws on both mounting brackets 4 Tilt up the bottom of the flat panel then set their kickstands against the bottom tubing of the mount Figures 2 3 You can now reach behind the flat panel for maintenance and servicing or replacement After servicing make sure the spring lock is locke...

Reviews: