Safet y
18
WBV.PU.002.EN VX186QD V2.0
WARNING
Skin and eye irritation caused by contact with hazardous working materials or media!
All work on the machine can lead to contact with working materials or media.
•
Personnel must wear suitable protective clothing.
•
The operator must inform his or her staff about any potentially hazardous substances in working
materials or media.
CAUTION
Risk of burning due to exposed host surfaces!
If the medium temperature is greater than 60 °C or the pump experiences dry running, the pump housing,
the connectors or the pipes can become very hot.
At high speeds or high differential pressure, the gearbox housing can also become very hot.
•
Avoid (accidental) contact with hot surfaces.
•
Avoid dry running of the pump, e.g. by means of dry running protection via
Temperature monitor
Level measurement
Flow measurement
ATTENTION
Risk of frost!
To protect the pump against damage caused by frozen medium, drain it when there is a risk of frost.
•
Drain the pump by running the pump in either direction (forward or reverse), until all liquid is drained
out of the pump. You can use drain cocks in the connectors to do this.
•
For complete draining of the pump chamber, remove the QD cover,
Chapter
"Opening the QD cover"
.
•
Before start-up, refill with fluid.
4.6
Main switch, maintenance and repair switch
All-pole disconnection must be provided for the main switch and maintenance and repair switch.
4.6.1
EMERGENCY STOP shutdown (main switch)
For shutdown in the event of an emergency, an emergency stop must be present and freely accessible at all
times.
4.6.2
Maintenance and repair switch
To safely exclude the possibility of unexpected machine start-up, a maintenance and repair switch must be
installed in the immediate vicinity of the electric drive so that the electrical power can be safely isolated for
maintenance purposes.
The maintenance and repair switch must be secured in its OFF position to prevent it being switched back on
again, using a padlock for example.
WARNING
Qualified technical personnel must connect and check the safety devices on a regular basis for proper
function, especially after performing maintenance and repair work and before start-up.