9.4
How the lobe puller works
Lobe puller
We recommend using two lobe pullers so the upper and lower lobes can be pulled off as simultaneously as
possible.
VX215-226QD:
part no. PBA.A001.TL
1
Hexagon head bolt
2
Puller arm
3
Pressure rod
Fig. 25: Lobe puller components
1.
Undo the four hexagon head bolts (1) so that the puller arms (2) can be moved.
2.
Hook the two puller arms (2) into the groove provided on the lobe
Fig.
"Hooking puller arm into
lobe".
3.
Tighten the hexagon head bolts (1) with approx. 50 Nm.
4.
Tighten the pressure rod (3) to dismount the lobe
Fig.
"Pulling out the lobes with lobe puller".
VX215-320QD:
part no. PBA.A001.T2
VX215-452/640QD:
part no. PBA.A001.T3
1
Hexagon head bolt
2
Puller arm
3
Pressure rod
4
Stabilisation
5
Wing nut
1.
Undo the four hexagon head bolts (1) and the wing nut (5) so that the puller arms (2) can be moved.
2.
Hook the two puller arms (2) into the groove provided on the lobe
Fig.
"Hooking puller arm into
lobe".
3.
Tighten the wing nut (5) and hexagon head bolts (1) with approx. 50 Nm.
4.
Tighten the pressure rod (3) to dismount the lobe
Fig.