Putting out of ope ration and dis pos al
WBV.PU.002.EN VX215QD V2.0
73
11 Putting out of operation and disposal
1.
Disconnect pump from the power supply or the PTO drive. Observe notices and safety notes
Chapter
"Drive".
2.
Disconnect pump from the pipe. Observe notices and safety notes
Chapter
"Installation in pipes".
WARNING
Risk of injury by crushing or impact!
Pipes under flexural strain can spring back under spring energy.
•
Personnel must wear suitable protective clothing.
•
Take care when undoing screws and bolts.
3.
Drain working materials.
Drain the gear oil from the pump gearbox. Observe notices and safety notes
Chapter
"Gear
oil
– inspection and change".
Drain the buffer or quenching fluid from the buffer chamber. Observe notices and safety notes
Chapter
"Draining and cleaning the buffer chamber".
4.
Drain the pump and remove residual medium. Observe notices and safety notes when opening the
pump cover
Chapter
"Repair".
Environmentally friendly disposal
Working materials such as oils, hydraulic fluids and dangerous media should be treated as hazardous waste
and disposed of properly.
5.
Hand over the pump for scrap. Observe notices and safety notes
Chapter