© 2022 United States Stove Company
11
PANEL CONTROLS
The blowers and automatic fuel supply are controlled from
a panel on the top of this unit. The control panel functions
are as follows.
A. ON/OFF SWITCH (“POWER” BUTTON)
• When pushed, the stove will automatically ignite. No
other fire starter is necessary. The igniter will stay on
for at least 10 and up to 12 minutes, depending on
when Proof of Fire is reached. The fire should start in
approximately 5 minutes.
•
The red light located above the “POWER” button will turn
green when pressed and remain green until the stove is
turned off.
•
After pushing “POWER”, the auger motor is on for 3.5
minutes, off for 1 minute. During the remainder of the
start-up period, the auger motor operates on the heat
range “1” setting.
•
During start up the heat level advance (Up and Down keys)
will change the heat range indicator level accordingly,
but there is no change in the stoves operating conditions
until start-up is completed.
• During start-up ignition must occur within 12 minutes or
the stove will error out and show E4.
•
During the start-up phase, the Mode key does not
function.
B.
LEVEL / TEMP ARROW BUTTONS
• These buttons when pushed will set the pellet feed rate,
hence the heat output or heat range of your stove.
• The levels of heat output will incrementally change on
the bar graph starting from heat range “1” to heat range
“5”.
C. °C / °F Button
• The °C / °F button changes the two digit display from
degrees Celsius to degrees Fahrenheit.
D.
MODE (M/T) BUTTON
•
The Mode of the stove can be switched between manual
and controlled with a Thermostat. Separate LEDs to
the left of the two digit display indicate the mode of
operation – Manual or T-Stat. The stove has to be in
normal operation to be switched from Manual to T-Stat
mode.
•
Manual mode operates according to the 5 set levels of
feed on the bar graph from heat range “1” to heat range
“5”.
T-Stat mode works as follows:
• The stove has a built in Thermostat into the controls
of the appliance. The temperature sensor for the T-Stat
is located on the back of the stove behind the display
board.
• Once the stove has gone into run mode the stove can be
switch into T-Stat mode.
•
The Up and Down Level / Temp Arrow buttons are used
to change the desired set-point temperature. Once the
desired temperature is reached the two digit display
will flash for four seconds and reset to the actual room
temperature.
• Once the stove reaches within 3°F of the desired
temperature set point, it returns to the heat range that
the stove was set on before it was switched to T-Stat
mode (if the stove was running on heat range “5” when
switched to T-stat mode when it gets within 3°F of the
set point it will return to heat range “5”).
• Once the stove reaches the desired set-point, the stove
will drop to heat range “1”.
• When room temperature drops below desired set-point
the stove will ramp back up until it reaches the desired
temperature.
HOW TO ADJUST THE FUEL ADJUSTER
It is a common occurrence in the pellet industry for the
average pellet size to vary. Due to the varying sizes of
pellets, this appliance is equipped with a fuel adjuster to
adjust the amount of fuel allowed to pass into the auger
assembly. The fuel adjuster is located inside the hopper.
Note: The factory default setting for this is full open. To
decrease the flow of pellets, move the fuel adjuster down.
OPERATION INSTRUCTIONS
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED