INSTALLATION
INSTALLATION OPTIONS
Freestanding Unit -
supported by pedestal/legs and
placed on a non-combustible floor surface in compliance
with clearance requirements for a freestanding stove
installation.
Alcove Unit -
supported by pedestal/legs and placed
on a non-combustible floor surface in compliance with
clearance requirements for an alcove installation.
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(ember protection) installed beneath it if the floor is of
combustible material. If a floor pad is used, it should
be UL listed or equal. The floor pad or non-combustible
surface should be large enough to cover at least the area
under the product and 6” (153 mm) beyond the front and
beyond each side of the fuel loading and ash removal
openings. Floor protection must extend under and 2” (51
mm) to each side of the chimney tee for an interior vertical
installation. Canadian Installations require a minimum of
18” [458 mm] beyond the front of the unit and 8” [204 mm]
beyond each side of the unit.
A
Side to Stove
U.S.A
6”
153 mm
CAN
8”
204 mm
B Front to Stove
U.S.A
6”
153 mm
CAN
18” 458 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please
adhere to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
C
Side Wall To Appliance
8”
204 mm
D Side Wall To Flue
3”
77 mm
E Back wall To Appliance
9.5” 242 mm
F Back wall To Flue
3”
77 mm
G
Wall To Corner Of Appliance
2”
51 mm
H Ceiling Height To Floor
60” 1524 mm
J
Ceiling Height To Appliance
27”
686 mm