Parameter
Minimum
Maximum
Default
Recommended
Settings
Unit
Line Side Voltage (Nominal
Voltage)
90
650
208
Supply voltage
Volts
Under /Over Voltage (tolerance)
6
18
12
10
%
Phase Unbalance
2
25
6
5
%
Lockout Time (Delay on Break)
0
720
30
120
Seconds
Delay Time (Delay on Make)
0
30
0
0
Seconds
Response Time (Delay on Fault)
0.1
20
2
2
Seconds
Control
Off / Auto / On
Auto
On
N/A
Contactor Test
OFF
5
OFF
OFF
Volt Diff
Table 10-2
Power Monitor Parameter Limits
Parameter Adjustments
Active display of
Line Voltage
(this is the default normal display).
Active display of
Load Side Voltage
(if connected).
Voltage Set Point (VAC Flashes)
. The value may be adjusted by pressing the up and down arrows.
This may be set to the normal operating voltage of the device being protected in one volt increments.
Under/over Voltage Tolerance in % (UNDERVOLTAGE/OVERVOLTAGE flashes).
The
value may be adjusted by pressing the up and down arrows.
Imbalance Voltage Tolerance in % (% IMBALANCE flashes).
The value may be adjusted by
pressing the up and down arrows.
Lockout Time in seconds (SECONDS flashes)
. The value may be adjusted by pressing the up and
down arrows. (This is the delay on break timer value)
Delay time in seconds and tenths of seconds (RESP. SECONDS flashes).
The value may be
adjusted by pressing the up and down arrows. This is the time that a fault is allowed before
shutdown occurs.
Control mode (ON OFF AUTO flashes).
The value may be adjusted to OFF (load will not turn
on), ON (load will turn on whenever there are not faults and timers are finished) and AUTO (Load
will turn on when there is a control input).
Contactor fault monitor mode (CONTACTOR FAULT flashes).
This option allows you to
monitor the contactor and lock it out if the line voltage and load side varies by more than 5 volts.
Pressing the up and down arrows selects off (default) or on. The load side of the contactor must be
connected to the load terminals of the DTP-3 to use this option.
Summary of Contents for P-24AL
Page 1: ...12 2016 P 24AL P 34AL TUBE ICE MACHINE Service Manual 5000 ...
Page 10: ...P24AL P34AL Service Manual TABLE OF CONTENTS 12 2016 vi ...
Page 15: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 5 Figure 1 2 P24AL Right Side ...
Page 16: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 6 Figure 1 3 P24AL Back Side ...
Page 17: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 7 Figure 1 4 P24AL Left Side ...
Page 18: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 8 Figure 1 5 P34AL Front Side Control Panel ...
Page 19: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 9 Figure 1 6 P34AL Right Side ...
Page 20: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 10 Figure 1 7 P34AL Back Side ...
Page 21: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 11 Figure 1 8 P34AL Left Side ...
Page 22: ...P24AL P34AL Service Manual INTRODUCTION 12 2016 1 12 ...
Page 62: ...P24AL P34AL Service Manual START UP OPERATION 12 2016 5 8 ...
Page 84: ...P24A P34A Service Manual TROUBLESHOOTING 12 2016 8 12 ...
Page 110: ...P24AL P34AL Service Manual SERVICING OPERATIONS 12 2016 9 26 ...
Page 126: ...P24AL P34AL Service Manual TABLES CHARTS 12 16 16 11 8 ...
Page 130: ...P24AL P34AL Service Manual INDEX 12 2016 12 4 ...
Page 131: ...Appendix A ...
Page 134: ......
Page 136: ...i ...
Page 137: ...ii ...
Page 138: ...1 ...
Page 139: ...2 ...
Page 140: ...3 ...
Page 141: ...4 ...
Page 142: ...5 ...
Page 143: ...6 ...
Page 144: ...7 ...
Page 145: ...8 ...
Page 146: ...9 ...
Page 147: ...10 ...
Page 148: ...11 ...