05TA Service Manual
TROUBLESHOOTING
7/19/13
8-3
SYMPTOM:
Machine won't run (CONT.)
POSSIBLE CAUSE
POSSIBLE REMEDY
Low oil pressure/Coresense tripped.
Note: Coresense replaced Sentronic oil safety
switch in March 2011.
If the machine stops because of low oil
pressure, the switch will have to be manually
reset. Check the crankcase oil level. Restart
the machine by pushing the "Start" push
button. Check the oil level and net oil pressure
(net oil pressure = pressure reading at the oil
pump end bearing housing minus suction
pressure). The oil level should be 1/4 - 3/4
level in the glass. If above 3/4, drain some oil
out. See Figure 9-11, Section 9 (Oil Pressure
Sensor ).
Cutter motor overload tripped.
Check and clear the cutter area and ice
discharge path of all ice. Check voltage and
overload range adjustment against motor
rating. Reset the switch and restart the
machine by the "Start" push button. Check the
cutter operation and motor amp draw. If
tripping repeats, but ice is not jammed, check
the cutter bearing for wear, the gear reducer
for resistance, and the motor for defect or
single phasing.
Pump motor overload tripped.
Check voltage and overload range adjustment
against motor rating. Reset the switch, set the
"Clean/Off/Ice" selector switch to the "Clean"
position and restart the machine by the "Start"
push button. Check the pump operation and
motor amps. If tripping repeats, check for a
defective overload, defective motor, or single
phasing.
Bin thermostat or bin level control stops
machine.
Adjust or replace the bin stat or level control.
Make sure bin stat bulb or level control is
located properly in the bin. See FIGURE 3-8,
Section 3 (Bin Thermostat).
Defective control panel component such as,
PF (Power failure relay), CC (Compressor contactor),
PB1 (Stop push button), CB3 (Control circuit breaker),
T (Harvest timer), Etc.
See FIGURE 6-3, Section 6 (Wiring
Schematic). Check for open circuit. Refer to
FIGURE 6-2, Section 6 (Control Panel) to
identify parts. Replace defective part, restart
machine and check power supply and current
draw.
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...