05TA Service Manual
OPTIONS AND ACCESSORIES
8/13/01
10-12
* (CMS) Compressor Motor Contactor
Provides power to the compressor motor. Continuously energized during freezing and thawing.
Auxiliary contact to provide power to oil pressure control and de-energize crankcase heater.
* (CB1) Circuit Breaker
Secondary pump/cutter motor protection.
*(CB2) Circuit Breaker
Air-cooled condenser fan motor protection.
*(CU) Cutter Motor Contactor With Overload Relay
Stops operation of cutter motor in the event of a mechanical or electrical malfunction resulting in
excessive motor amperes.
*(P) Pump Motor Contactor With Overload Relay
Stops operation of water pump motor in the event of a mechanical or electrical malfunction
resulting in excessive motor amperes.
*(PLC) Programmable Logic Controller
For monitoring, sequencing, and controlling various functions of machine operation.
*(FTB-1) Fused Terminal Block
Overload and short-circuit protection for PLC outputs.
*(FC) Fan Contactor
Cycles the fan motor(s) of air-cooled condenser on and off. Activated by the condenser pressure
switch (air-cooled machines only).
*(TS1) Ice/Clean Toggle Switch
Two position toggle switch to operate machine in ice making mode or clean mode. When in clean
position, only the water pump will run. This allows cleaner to be circulated through the freezer
without making ice.
*(TS2) On/Off Toggle Switch
Two position switch used to stop machine at the end of the harvest and restart the machine in a
freeze cycle.
*(ET) Elapsed Time Indicator
Indicates hours of machine operation. Energized when compressor is operating.
*(PB1) Stop Push Button (Red)
Used to stop machine immediately.
*(PB2) Start Push Button (Green)
For starting machine or manually harvesting. Will initiate a harvest cycle whenever pushed with
“Ice/Clean” switch in “Ice” position.
*(TB) Terminal Block
Numbered for multiple wire connections and ease of troubleshooting.
*(FU1, FU2) 2.5 Amp Fuses
Overload and short circuit protection for crankcase heater and the control circuit.
*(FPS) Freezer Pressure Switch
For regulating the ice thickness by sensing freezer pressure switch and initiating the thaw period.
FIGURE 10-3 (cont.)
Control Panel Parts
Summary of Contents for TUBE-ICE 05TA
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Page 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Page 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Page 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...