5 Cabling and wiring
5.1 Electrical safety
To avoid electrical hazards please note the following:
• Only connect electrical equipment to 50-60 Hz AC power outlets rated at 100-
120 VAC or 200-240 VAC
• Do not supply electrical power to equipment without a safety ground connection
• Do not supply electrical power to equipment that has been exposed to moisture (e.g. rain)
• Do not supply electrical power to equipment that has become coated in moisture (e.g.
condensation)
• Do not access the inside of any electrical equipment. Refer servicing to Void-approved
service agents.
5.2 Cable considerations for fixed installations
We recommend specifying installation-grade Low Smoke Zero Halogen (LSZH) cables for
permanent installations. The cables should use Oxygen Free Copper (OFC) of grade C11000
or above. Cables for permanent installations should be compliant with the following standards:
• IEC 60332.1 Fire retardancy of a single cable
• IEC 60332.3C Fire retardancy of bunched cables
• IEC 60754.1 Amount of Halogen Gas Emissions
• IEC 60754.2 Degree of acidity of released gases
• IEC 61034.2 Measurement of smoke density.
We suggest using the following maximum copper cable lengths to keep level losses below 0.6 dB.
Arcline cabinets in parallel
2 x Arcline 8
4 x Arcline 8
1 x Arcline 212
2 x Arcline 212
Metric mm
2
Imperial AWG
8
Ω
load
4
Ω
Load
2.5 mm
2
13 AWG
36 m
18 m
4 mm
2
11 AWG
60 m
30 m