background image

VOKERA

If the Amber LED on the receiver is flashing radio contact between the room unit and the receiver has
been lost (it is therefore worth checking the battery indicator on the room unit).

A solid red LED is not a fault indication, it simply indicates the unit is powered on.

A solid amber LED indicates there is an external sensor fitted.

11: Fault codes on the OpenTherm control (room unit):

Faults codes may be displayed on the room unit, but if the heating mode is OFF, no fault code is
displayed.

For further instructions relating to fault codes and system parameters, please refer to the OpenTherm
Quick help guide on our website 

A01: Ignition fault on boiler

A02: Boiler overheat

*

A03: Fan or flue problem

A04: System water pressure too low

A05: Electrical or boiler control board problem

A06: Domestic hot water sensor problem (the boiler will still produce hot water for the user while
showing this fault condition but using the flow thermistor will lock to 65°C which will provide warm water
for washing only. The temperature will not be adjustable on the room unit until repaired). 

A07: Flow temperature fault

A08: Return temperature fault

A09: Flue temperature fault or service reminder (the boiler will still work as normal with a service
reminder alarm indicated.

*

Any faults shown on the room unit with an A2XX code can be reset on the boiler control only, not at

the receiver.

12: Setting the parameters on the OpenTherm Control:

There are a set of default parameters ready programmed into the OpenTherm Control

The adjustment should generally be by the engineer not the end user however there are two that the
end user may need to adjust the heating curve and the value regarding the insulation of the property.

To enter parameter or engineer mode.

Press the     button

Press the     button 5 times until PL appears in the screen

Summary of Contents for OpenTherm 711

Page 1: ...stem which may still be connected When the OpenTherm Control is connected to your boiler with an external weather compensation sensor fitted the room unit operates and displays differently than when n...

Page 2: ...om unit 5 Setting the heating temperature levels and the times 6 Selecting heating modes on the OpenTherm Control 7 Fast adjustment of the room temperature 8 Adjusting the hot water temperature 9 Rese...

Page 3: ...fort temperature At all other times the OpenTherm will maintain an economy temperature Saturday and Sunday 08 00 to 11 00 and 16 00 to 23 00 at comfort temperature At all other times the OpenTherm wil...

Page 4: ...omy level Press the button twice A filled timeline sun icon and temperature appear indicating the current comfort level Use the or plus buttons to select your desired comfort level temperature Once th...

Page 5: ...functions which can be selected by pressing the heating mode button One press of the button will take you to party mode The party mode is represented by the icon which will appear on the left side of...

Page 6: ...adient on the right of the screen will change a tap icon will flash and the hot water temperature will appear in the large house icon Press the button once to lock the setting If you do not press the...

Page 7: ...sensor problem the boiler will still produce hot water for the user while showing this fault condition but using the flow thermistor will lock to 65 C which will provide warm water for washing only Th...

Page 8: ...ust the OpenTherm Control to suit the insulation level of the property The scale is 1 to 20 with 1 being a well insulated house and 20 a poorly insulated house The unit default is 10 13 The room unit...

Page 9: ...tween the display of the actual boiler flue temperature and the number of hours in condensing mode the boiler has operated x100 2500 hours signals the need for a full service A09 will be displayed on...

Reviews: