10
to any back or infill panel.
In accordance with BS 5871 part 2, minimum debris collection volumes are required behind the installed
appliance.
CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY ONLY USED WITH A
GAS FIRE.
Appliance recessed depth + 20mm
UNLINED FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID FUEL OR OIL
BURNING APPLIANCE
Appliance recessed depth + 60mm
Always ensure that the gas supply is isolated before commencing installation of the appliance.
The fireplace opening and environment must be in compliance with specifications laid down in the
appropriate sections of these instructions.
Remove the appliance from its carton as described previously and stand on a dust sheet, place the
coals, ceramics and fixings safely to one side.
Remove the burner from the assembly by removing the 4 x Screws at the top of the glass panel, with
the glass door dropped down you can lift the door off its hinges to allow ease of access to the fire box
and the burner, start by removing the ceramic pads over the burner and gentle put this to one side to
avoid any damage.
Section 7: INSTALLATION OF THE APPLIANCE
Section 6: DEBRIS SPACE