27
2.
Release the pressure and the pilot light should now be established (if this fails repeat step
1 and hold down for 20 seconds).
3.
Slide the control to the left to increase the flame size to the desired effect.
4.
To switch the fire off simple slide the control all the way to the left, passed the positive
stop.
Code
Comment
Appearance
Possible Cause
Action
E00
TESC locked due to
failed ignition
Red Led is
permanently on
TESC unit ( and
E00 on handset, if
used)
Temporary air
disturbance
around pilot
burner
Reset control by pressing
start button for 1 second
and releasing. The press
again the same way to
attempt a normal start
command. Repeat up to 10
times as necessary to see
if this overcomes the issue
as it may resolve itself
eventually.
No gas on
appliance inlet
Check to see if gas is
present at gas appliance
inlet. (Check gas supply is
on, the gas line purged of
air and the supply
pipework is free of
blockages or
contamination)
Rectify and perform
start cycle to clear
the Error code. Try
to light the fire as
normal.
Pilot contaminated
with lint or other
materials
Clean the pilot fee of any
dirt, dust carbon granules
or lint, especially around
the brass body of the
Bunsen burner and its gas
and electrical connection
and the area around the
flame ports and the spark
plug and electrode tip.
Check the electrode gap is
3- 4 mm.
Rectify and perform
start cycle to clear
the Error code. Try
to light the fir as
normal. Replace
pilot if necessary
SECTION 17a: Remote Error Trouble Shooting Guide