01-128
Switch to measuring range:
Resistance measurement (200
/20 M
)
Test
step
V.A.G
1598
sockets
Item tested
Test conditions
- Additional
operations
Specification
Measures for
deviations from
specification
20
-
Longitudinal
acceleration
sensor -
G251- wiring
Ignition switched
off
Select 200
measuring range
- Disconnect
connector for
longitudinal
acceleration sensor -
G251-
- Disconnect multi-pin
connector T25 from
ABS control module
(w/EDL) -J104-
- Connect test box
V.A.G 1598/21
- Check wiring
between multi-pin
connector for
longitudinal
acceleration sensor -
G251- and multi-pin
connector for ABS
control module
(w/EDL) -J104- for
open circuit
max. 1.5
Electrical Wiring
Diagrams,
Troubleshooting &
Component
Locations binder
- Check wiring
using wiring
diagram
Test step 20: Continued on next
page.
Стр
. 27
из
31
ABS, ABS/EDL and ABS/EDL/ASR ITT Mark 20 IE, electrical check