01-267
Rapid data transfer
Q
04 - Basic setting
Indicated on display:
- Confirm entry with key Q.
Basic setting HELP
Enter display group number XXX
Indicated on display:
The following cycle of steps must be
repeated 8 times according to the basic
setting prescribed by V.A.G 1551 or
tester VAS 5051.
- Press keys 0, 0 and 1
- Confirm entry with key Q.
Basic setting 1 ON
Depress pedal and hold...
Indicated on display:
- Operate pedal with substantial foot
pressure and hold.
Pedal moves down
Hydraulic pump runs
Pedal comes back
Basic setting
1
Rel. pedal; FR/FL bleed screw OPEN
Indicated on display:
- Press key 3 on V.A.G 1551 or arrow up
key on VAS 5051
Basic setting 1 ON
Please wait...(10 secs.)
Indicated on display:
Hydraulic pump runs
Стр
. 109
из
129
On Board Diagnostic (OBD), performing